Omnitron Systems Technology, Inc.
DEMUX-STAR LINK ADDR
BIT 1
BIT 2
BIT 3
POLARITY CONTROL (U Models)
MUX LINK 1
HOST LINKS 0-7
RX
DEMUX-STAR
DEMUX
MUX
STAR
FUNCTION CONTROL
LINK CONTROL
1 2 3 4 5 6 7 8
LOCAL
DISTANT
HOST MASTER
LINK (DB25)
POWER
Figure 1. OmniMux 400 rear view
Power-Up
In order to minimize the possibility of accidental power shut off to the OmniMux 400,
no power switch has been designed into the product. Special care must be taken
when applying power to the OmniMux unit.
WARNING
The OmniMux unit does not have a power switch,
so extra care must be taken in powering the unit.
Always plug the Power Adapter into the back of
the Mux unit first. This is in order to prevent
damage to the Mux unit and to prevent potential
shorts, sparks, and fire hazards.
Verify that the power supply voltage (by reading the label on each power adapter
unit) is consistent with the facility’s line voltage (115/230 Volts), and that the Power
Adapter plug fits in the outlet.
Plug the Power Adapter’s cable connector to the appropriate matching connector
in the back of the OmniMux Unit.
Plug the Power Adapter into the wall outlet. Observe that all LED’s light up for
approximately 0.5 seconds. After 0.5 seconds, all should extinguish except the
yellow power LED; It stays On.
Control Switches
The following figure depicts a rear view of the OmniMux 400. There are two Switch
Banks which control the operation of the OmniMux 400.
Omnitron Systems Technology, Inc.
7
DEMUX-STAR LINK ADDR
BIT 1
BIT 2
BIT 3
POLARITY CONTROL (U Models)
MUX LINK 1
HOST LINKS 0-7
RX
DEMUX-STAR
DEMUX
MUX
STAR
FUNCTION CONTROL
LINK CONTROL
1 2 3 4 5 6 7 8
LOCAL
DISTANT
Switch #
Position
Function
Notes
1
X
Controls UTP Hosts Link Polarity
No affect in model 2701
2
X
Controls UTP Mux Link 1 Polarity
No affect in model 2701
3
X
RX Polarity
Reserved for future applications
4,5
U,U
U,D
D,U
D,D
Star Configuration
Mux Configuration
Demux Configuration
Demux-Star Configuration
6,7,8
X
Demux-Star Link Address
Affect only during Demux-Star Application
Function Control
This is an eight-switch bank which includes the following functions (Figure 2):
Figure 2. Function Control Switch Block
Link Control