Omnitron Systems Technology iConverter 2GXM2 Standalone Module User Manual
Page 2
Connect the power wires to the DC power source. The Power LED should indicate
the presence of power.
waRNING: Note the wire colors used in making the positive and negative
connections. Use the same color assignment for the connection at the DC
power source.
NOTE: If mounting with a safety ground attachment, use the safety ground
screw at the rear of the unit.
b. Insert the SFP Fiber transceivers into the Port 1 and Port 2 SFP receptacles on the
2GXM2.
NOTE: The release latch of the SFP Fiber transceiver must be in the closed
position before insertion.
c. Connect an appropriate multimode or single-mode fiber cable to the SFP fiber ports
of the installed module. It is important to ensure that the transmit (Tx) is attached to
the receive side of the device at the other end and the receive (Rx) is attached to
the transmit side. Single-fiber (SF) media converter models operate in pairs. The Tx
wavelength must match the Rx wavelength at the other end and the Rx wavelength
must match the Tx wavelength at the other end
NOTE: In order to support Remote OaM Management Mode, Port 1 of the
2GXM2 must be connected to the Port 1 on the 2GXM2 or link partner.
3) CONFIGURE MODUlE VIa COMMaND lINE INTERFaCE
To access the Command Line Interface (CLI), connect the 2GXM2 RS-232 Console
Port to the COM port of a computer equipped with terminal emulation software such
as HyperTerminal. The Console Port (DCE) is a mini DIN-6 female connector which
can be changed to a DB-9 connector with the included adapter. The 2GXM2 Console
Port is a standard asynchronous serial interface.
Start HyperTerminal and select the correct COM Port in the HyperTerminal “Connect
To:” window. Set the serial port to the following:
Bits Per Second
57,600
Stop Bits
1
Data Bits
8
Parity
NONE
Hardware Flow Control
NONE
Once connected, press <ENTER> to bring up a command line prompt on the attached
PC. A new 2GXM2 module does not have a password, and will skip the Password
Entry screen and go straight to the Management Options screen. If a password has
been set, the Password Entry screen will be displayed. Type the password and press
<ENTER>, the 2GXM2 will respond with the Management Options screen:
should be set to the UP Manual “MAN” position. See Figure B for more information.
NOTE: when Port 1 operates in auto-Negotiation mode, the port advertises
Pause. when the Fiber optic ports (Port 1 and Port 2) operates in Manual mode,
Pause is not advertised.
NOTE: The fiber optic ports operate in Full-Duplex mode in both auto and Manual
negotiation modes.
Sw3, Sw4, Sw5 - RESERVED
These DIP-switches are for factory use only and must always remain in the DOWN
position (factory default).
Sw6, Sw7, Sw8 - lINk MODES
These three DIP-switches configure the link mode settings. The following table details
possible Link Mode DIP-switch configurations. For detailed information on the operation
of the different Link Modes, download the application note “iConverter Link Modes”
available on Omnitron’s web page:
http://www.omnitron-systems.com/downloads.php
Figure B: DIP-Switches
2) INSTall STaNDalONE MODUlE aND CONNECT CaBlES
a. The 2GXM2 Network Interface Device (NID) is available in tabletop and wall-
mounting models. For wall-mounting, attach the NID to a wall, backboard or other
flat surfaces. For tabletop installations, place the unit on a flat level surface. Attach
the rubber feet to the bottom of the NID to prevent the unit from sliding. Make sure
the unit is placed in a safe, dry and secure location.
To power the unit using the AC/DC adapter, connect the AC/DC adapter to the AC
outlet. Then connect the barrel plug at the end of the wire on the AC/DC adapter
to the 2.5mm DC barrel connector (center-positive) on the chassis. Confirm that
the unit has powered up properly by checking the power status LED located on the
front of the unit.
To power the unit using a DC power source, prepare a power cable using a two-
conductor insulated wire (not supplied) with a 14 AWG gauge minimum. Cut the
power cable to the length required. Strip approximately 3/8 of an inch of insulation
from the power cable wires. Connect the power cables to the standalone unit by
fastening the stripped ends to the DC power connector.
Page 2
Page 3
Switch
Down
(Factory Default)
Up
Sw1
aN:
Fiber Port 1 Auto
Man:
Fiber Port 1 Manual
Sw2
aN:
Fiber Port 2 Auto
Man:
Fiber Port 2 Manual
Sw3
Reserved
Reserved
Sw4
Reserved
Reserved
Sw5
Reserved
Reserved
Sw6
See link Mode Section
Sw7
Sw8
Sw6
Sw7
Sw8
link Mode Selection
Down
Down
Down
link Sement (lS)
(Factory Default)
Up
Down
Down
link Propagate (lP)
Down
Up
Down
Remote Fault Detect + link
Segemnt (RFD + lS)
Up
Up
Down
Remote Fault Detect + link
Propagate (RFD + lP)
Down
Down
Up
Symmetrical Fault Detect
(SFD)
Up
Down
Up
asymmetrical link Propagate
Port 1 to Port 2 (alP P1-P2)
Down
Up
Up
asymmetrical link Propagate
Port 2 to Port 1 (alP P2-P1)
Up
Up
Up
Pass Remote link Fault
(PRlF)