beautypg.com

Line configuration/layout – Multiquip MQ600TD80 User Manual

Page 17

background image

mq600Td80 TRaSH pUmp• opeRaTion and paRTS manUal — Rev. #11 (10/10/11) — page 17

line cOnFiGuratiOn/layOut

The pump performance is adversely affected by increased

suction lift. Place the pump as close as possible to liquid

being pumped. Always place pump on level ground to

insure sufficient engine lubrication and fuel supply. If

trailer-mounted, pump block wheels before operation. The

lines near the pump must be properly supported. Never

use shut-off valves.

SUCTion line

Use appropriate 6-inch diameter hoses, the suction hose

must be rigid, reinforced to prevent collapse under suction.

To prevent air pockets, the suction hose must be straight

short as possible; the line must always slope upward from

the water source to the pump. The line should not slope

down or air pockets may occur. If liquid being supplied to

pump is under pressure, the incoming pressure must be

limited to 50% of the maximum operating pressure based

on the pump engineering data curve.

diSCHaRged line

Maintain discharge lines straight as possible to prevent

whipping and reduce friction loss. The line friction can be

reduced with minimal use of fittings and elbows. If using

elbows, wide radius is preferred. Always use strainer

furnished with the pump.

FiTTingS

Use properly rated 6-inch size fittings. Align fittings to pump

before tightening connections. The pump connections

should be sealed with pipe sealant to ensure air tight seal. A

slight leak will affect priming ability and output performance