0 fatigue templates, Fatigue templates – MTS Multipurpose Simulated User Manual
Page 19

If you run a simulated test and then want to run a different template, you must use the MPE application to
disconnect from the controller (Controller > Disconnect), use the Station Manager application to open the
configuration file required for the new template (see the table below), and then use the MPE application to
connect to the controller (Controller > Connect).
Simulation Controller Configuration Files and Test Names
Template Name
Controller Configuration
File
Test Type
HCF Load Test.tsproj
Virt_3-02_CF_HCF.cfg
ASTM High-Cycle Fatigue (HCF)
Load
(Sample Test Not Available)
Virt_3-02_CF_LCF with
Temperature.cfg
ASTM Low-Cycle Fatigue (LCF) with
Elevated Temperature
Sample LCF Strain Test.tsproj
Virt_3-02_CF_LCF.cfg
ASTM Low-Cycle Fatigue (LCF)
Strain
Transition Test.tsproj
Virt_3-02_CF_LCF.cfg
Transition Test
Trapezoidal Test.tsproj
Virt_3-02_CF_LCF.cfg
Trapezoidal Test
FCG Compliance Tension.tsproj
Virt_3-02_FCG.cfg
ASTM E 647 Fatigue Crack Growth
Compliance
FCG DCPD.tsproj
Virt_3-02_FCG_DCPD.cfg
ASTM E 647 Fatigue Crack Growth
Tension DC Potential Drop (DCPD)
CTOD Tension.tsproj
Virt_3-02_FT_CTOD.cfg
ASTM E 1290 Crack-Tip Opening
Displacement (CTOD)
JIC Tension.tsproj
Virt_3-02_FT_JIC.cfg
ASTM E 1820 JIC
KIC Tension.tsproj
Virt_3-02_FT_KIC.cfg
ASTM E 399 KIC
3.3.0 Fatigue Templates
Low-Cycle Fatigue (LCF)
The following templates are available for LCF tests and analysis:
MTS TestSuite 19
3.0 Controller Simulation Overview