Fault messages

7

l

95

EDBPM−H410 DE/EN/FR 4.1

7

Troubleshooting and fault elimination

7.1

Fault messages

Call up the status messages of the operating unit to indicate the last fault
message. (

82)

Display

Fault

Cause

Remedy

NO ERROR

No fault

PR ERROR

Faulty data
exchange

Connection between
operating unit and PC is
faulty

l

Check connections for tight fit

l

Check cable for damage

COM BROK

Communication
interrupted

Serial data cable between
operating unit and PC is
defective or not correctly
connected

l

Check correct connection and
tight fit of Sub−D plug

l

Exchange serial data cable

RESET ERROR Communication

with system
bus (CAN)
interrupted

l

Faulty wiring
(e.g. polarity) of the
system bus

l

Faulty parameter
setting of interface
(baud rate, address,
identifier)

l

Check wiring (

^

73)

l

Check parameter setting
(

^

HMI Designer − Getting

started).)

ASIC ERROR

SDO ERROR