3 calling up information messages, Calling up information messages, Operation – Lenze EPM−H410 User Manual
Page 90
Operation
Calling up information messages
l
90
EDBPM−H410 DE/EN/FR 4.1
6.3
Calling up information messages
ƒ
Information messages
–
are texts which appear because of a certain event (e.g. if an actual value
exceeds a limit).
–
can only be called up as long as the triggering event is active.
–
must have been programmed in the "HMI Designer" planning tool.
–
can have a length of up to 5 lines × 30 characters (normal character
size).
ƒ
The second to last line contains a programmable message field. This field
indicates the numerical value of the variable that has activated the
message.
ƒ
The last line shows the date and time when the message was triggered.
ƒ
The LED in the
Info
key will flash if an information message is available.
Symbols and characters in the information messages
Symbols/characters used in the line for
date/time
Meaning
*
The information message has been called up for
the first time
HELP
Help is assigned to the information message.
(
You want to ...
Press keys ...
Example
A
call up an information message.
Info
Druck uebersteigt
die Sicherheitsgrenze
125.5
13-09-2000 10:45a
HELP
PdDn
B
select the next information message.
shift
+
PgDN
Temperatur uebersteigt
PgUp
die Sicherheitsgrenze
1700
13-09-2000 10:45a
HELP
C
close the information message.
Clr
Esc