Emf2179ib communication module (devicenet) – Lenze EMF2179IB User Manual
Page 73

EMF2179IB communication module (DeviceNet)
Lenze codes and DeviceNet objects
Implemented DeviceNet objects
5
5.7
5.7.2
5.7-14
EDSDEN EN 02/2006
Instance 0:
Attribute
Service(s)
Description
Data type
Value
1
GET
Revision
UINT
0001
hex
Instance 1:
Attribute
Service(s)
Description
Data type
Value
1
GET/SET
I/O data
length in
words
UINT
1 – 12 (0000
hex
– 000C
hex
),
Default: 2, (saved in EEPROM)
Services:
Service code
Name
Description
0E
hex
Get_Attribute_Single
Reading of an attribute
10
hex
Set_Attribute_Single
Writing of an attribute
Note!
ƒ
If the I/O data length is changed, the DeviceNet scanner will
be informed about this change (produced/consumed data
size).
ƒ
If the I/O data length is reduced, it must be checked before, if
the intended data length is sufficient for the application.
ƒ
The parameters of 66
hex
are described in the EDS file and
therefore can be directly set in the feature dialog of the
DeviceNet nodes under ”Parameters” via the »RSNetWorx«
Rockwell software.
ƒ
In case of a number of process data words deviating from the
Lenze setting (2 words), the ”Automap on Add” function in the
scanner configuration dialog of the »RSNetWorx« software
has to be deactivated, and the number of process data words
has to be adjusted via the ”Edit I/O parameters” button.
Manufacturer-specific class
102 (66
hex
)