Appendix, Show/hide bookmarks – Lenze EMF2102IB User Manual
Page 46

Appendix
8-14
L
_^ONMObk
Code
Note
Name
C0249
*
LECOM code bank
(P2102)
Code bank
Code number
0
0
to
255 (Factory setting)
1
250
to
505
2
500
to
755
3
750
to
1005
4
1000
to
1255
5
1250
to
1505
6
1500
to
1755
7
1750
to
2005
8
2000
to
2255
9
2250
to
2505
10
2500
to
2755
11
2750
to
3005
12
3000
to
3255
13
3250
to
3505
14
3500
to
3755
15
3750
to
4005
The LECOM code bank ensures the compatibility with the master-system drivers according to the LECOM-A/B specification V1.0.
The maximum code number is 255. With the code bank, an offset of 250 is added to the code number.
The code bank addressing is not effective with extended code addressing (LECOM-A/B specification).
The parameter value is always set to 0 when switching on.
LECOM format: VD
C1810
*
SW labelling
(P2102)
33S2102I_xy000
Software labelling of the 2102IB fieldbus modules
x = main SW version
y = SW subversion
LECOM format: VS
C1811
*
SW generation
(P2102)
Software generation of the 2102IB fieldbus module
LECOM format: VS
C1920
Start status
(P2102)
0
QSP
1
Controller inhibit
LECOM format: VD
C1922
Monitoring selection
code
(P2102)
0
Not active
1
Controller inhibit
2
QSP (quick stop)
LECOM format: VD
C1921
Shortened response
time
(P2102)
0
Not active
1
active
LECOM format: VD
C1923
Monitoring time
(P2102)
50 to 65535ms
LECOM format: VD
C1962
Extended code No.
See fault table
Show/Hide Bookmarks