Commissioning, Handling of the keypad – Lenze 8400 motec Manual User Manual
Page 85

Commissioning
Handling of the keypad
l
85
EDS84DG752 EN 4.0
User menu
The user menu can be freely configured in C00517 and contains the following parameters
in the Lenze setting:
Parameter
Name
Info
Lenze setting
Value
Unit
C00002/19 Device command:
Reset error
After resetting the current error, further errors may be
pending which must be reset as well.
Details of the current error are displayed in C00166.
0
−
C00007
Control mode
Selection of how the application is to be controlled.
10
−
C00011
Appl.: Reference
speed
Setting the reference speed
1500
rpm
C00012
Accel. time − main
setpoint
FB L_NSet_1: Acceleration time of the ramp generator
for the main speed setpoint
2.0
s
C00013
Decel. time − main
setpoint
FB L_NSet_1: Deceleration time of the ramp generator
for the main speed setpoint
2.0
s
C00015
VFC: V/f base
frequency
V/f base frequency for VFCplus motor control
50
Hz
C00016
VFC: Vmin boost
Boost of the V/f voltage characteristic within the
range of low speed or frequency values for the
VFCplus motor control.
2.6
%
C00022
Imax in motor mode Maximum current in motor mode for all motor control
modes
5.8
A
C00039/1
Fixed setpoint 1
(L_NSet_1 n−Fix)
FB L_NSet_1: Fixed speed setpoints (JOG values) for
the setpoint generator
Fixed setpoint 1
40.0
%
C00039/2
Fixed setpoint 2
Fixed setpoint 2
60.0
%
C00039/3
Fixed setpoint 3
Fixed setpoint 3
80.0
%
C00087
Rated motor speed
This value can be obtained from the motor nameplate.
After the motor to be used has been selected from the
motor catalogue,
the suitable value can be entered automatically.
1320
rpm
C00089
Rated motor
frequency
This value can be obtained from the motor nameplate.
After the motor to be used has been selected from the
motor catalogue,
the suitable value can be entered automatically.
50
Hz
C00105
Deceleration time −
quick stop
The set deceleration time determines the ramp slope
at quick stop
5.0
s
C00120
Motor overload
threshold (I
2
xt)
Operating threshold for the error message "OC6:
Motor overload (I
2
xt)"
100
%
C00129
Value brake resistor
Resistance value of the connected brake resistor
220
W
C00165
Error information
Display of the error numbers divided into sectors in
the case of an error
−
−
C00173
Mains voltage
Selection of the mains voltage for operating the
device.
0: 400 V
−
C02580
Holding brake:
Operating mode
Selection of the operating mode for holding brake
control
0: Off
−