1 mains connection, 2 motor connection, 3 motor temperature monitoring – Lenze 8400 motec Manual User Manual
Page 45: 4 motor holding brake connection, 5 connection of brake resistor, Mains connection, Motor connection, Motor temperature monitoring, Motor holding brake connection, Connection of brake resistor

Technical data
Power terminals
Mains connection
l
45
EDS84DG752 EN 4.0
4.6.1
Mains connection
Pin / name
Features
Rated value
L1, L2, L3
Mains phases
according to rated data
assigned X1:
+
Earthing, 2 x in the Wu
−
4.6.2
Motor connection
Pin / name
Features
Rated value
U, V, W
Motor phases
according to rated data
assigned X1:
+
Earthing, 2 x in the Wu
−
4.6.3
Motor temperature monitoring
Pin / name
Features
Rated value
T1, T2
Motor temperature monitoring
according to rated data
4.6.4
Motor holding brake connection
Pin / name
Feature
Rated value
BD1 (+)
BD2 (−)
Connection of a motor holding brake
Output voltage
(depending on mains voltage)
AC 400 V
DC 180 V
AC 480 V
DC 215 V
Max. output current
0.3 A
Max. output power
55 VA
Time−dependent behaviour
See software manual, chapter "Holding brake
control/parameter setting"
Short−circuit strength
No
Reset and switch−on behaviour
Outputs are switched off
Operating frequency
Max. 30/min
4.6.5
Connection of brake resistor
Pin / name
Features
Rated value
Rb1, Rb2
Brake resistor
according to rated data