Commissioning, Quick commissioning general configuration settings, Possible settings with dip1 – Lenze 8400 motec Manual User Manual
Page 79: Possible settings with dip2

Commissioning
Quick commissioning
General configuration settings
l
79
EDS84DG752 EN 4.0
Possible settings with DIP1
(Lenze setting bold)
DIP1
Switch
Description
1
2
3
4
5
6
7
8
Settings after DIP1, DIP2, P1, P2, and
P3 active
on ( I )
ON
off ( 0 )
OFF
Direction of rotation
left
ON
right
OFF
Control
quadratic
ON
linear
OFF
Flying restart circuit
on ( I )
ON
off ( 0 )
OFF
Reserved
−
OFF
OFF
OFF
Message type −> on
(only optional with Communication
Unit "+ Safety")
fail −> DO
ready −> NO (relay)
ON
ready −> DO
fail −> NO (relay)
OFF
Possible settings with DIP2
DIP2
Switch
Description
1
2
3
4
5
6
7
8
Rated motor frequency
50 Hz
OFF
OFF
60 Hz
ON
OFF
87 Hz
OFF
ON
120 Hz
ON
ON
Mode of the analog input
(only optional with Communication
Unit "+ Safety")
0 ... 10 V
OFF
OFF
0 ... 20 mA
ON
OFF
4 ... 20 mA
OFF
ON
not permissible
ON
ON
Control mode of technology
application
(cf. selection C00007)
9 (local mode)
OFF
OFF
OFF
10 (terminals 0)
ON
OFF
OFF
12 (terminals 2)
OFF
ON
OFF
14 (terminals 11)
ON
ON
OFF
16 (terminals 16)
OFF
OFF
ON
Reserved
ON
OFF
ON
Reserved
OFF
ON
ON
40 (MCI)
ON
ON
ON
Reserved
−
OFF