Technical data – Lenze 8400 motec Manual User Manual
Page 29
Technical data
General data and operating conditions
l
29
EDS84DG752 EN 4.0
EMC
Noise emission (in TN and TT mains)
Cable−guided
EN 61800−3
Motor mounting
E84DVBM3714 ... 1524
Category C1
E84DVBM2224 ... 3024
for switching frequency
£ 4 kHz
Category C1
E84DVBM4024 ... 7524
Category C2
Wall mounting
EN 61800−3
E84DVBW3714 ... 7524
for switching frequency
£ 4 kHz and
with Lenze system cable
£ 20 m
Category C2
E84DVBW3714 ... 7524 for
switching frequency
£ 8 kHz and
with Lenze system cable
£ 10 m
Category C2
Radiation
EN 61800−3
E84DVBM3714 ... 1524
for switching frequency
£ 8 kHz
Category C1
E84DVBM2224 ... 7524
for switching frequency
£ 8 kHz
Category C2
Noise immunity (according to requirements of EN 61800−3)
Electrostatic discharge
(ESD)
EN 61000−4−2
8 kV with air discharge,
4 kV with contact discharge against housing
Radio frequency
Conducted
EN 61000−4−6
150 kHz ... 80 MHz, 10 V/m 80 % AM (1kHz)
Interference
(housing)
EN 61000−4−3
80 MHz ... 1000 MHz, 10 V/m 80 % AM (1kHz)
Burst
Power terminals and
interfaces
EN 61000−4−4
2 kV/5 kHz
Signal interfaces
EN 61000−4−4
1 kV/5 kHz
Control terminals
EN 61000−4−4
2 kV/5 kHz
Surge
Power terminals
EN 61000−4−5
1.2/50
ms,
1 kV phase/phase, 2 kV phase/PE
Control terminals
EN 61000−4−5
1.2/50
ms, 1 kV
Operation on public
supply systems
EN 61000−3−2
EN 61000−3−12
The devices are intended for use in an industrial
environment. When being used on public network, additional
measures must be taken to limit the expected radio
interference. The compliance with the requirements for the
machine/plant is the responsibility of the manufacturer of
the machine or system!
Voltage deviations
Voltage dips
EN 61800−3
Short mains voltage dips (comp. IEC 61000−2−1) can lead to a
switch−off of the motor.