beautypg.com

Hydraulic installation, Warning – Landoll WFPC38-52 Wing Float Pulverizer User Manual

Page 24

background image

2-10

F-661-R2

ASSEMBLY

Hydraulic Installation

WARNING

Remove Fitting Caps prior to installing Fittings.

NOTE

The Magnet provided is used to prevent hoses from
dragging with drawbar extended.

Assemble the Magnet and related components to the
hoses. Position halfway between drawbar assembly and
hose support.

Figure 2-9: Hydraulic Installation

Escaping fluid under pressure can be nearly
invisible and have enough force to penetrate the
skin causing serious injury. Use a piece of
cardboard, rather than hands, to search for
suspected leaks. Wear protective gloves & safety
glasses or goggles when working with hydraulic
systems.

Hose

Support

Handle

Hose Clamp

Magnet

HHCS,5/16-18 x 2-1/4

Flat Washer,5/16

Elbow,08MOR x

08FJS x 90°

Remove

Fitting Caps

Female Coupler

TIGHTENING PROCEDURE FOR

JIC 37° SWIVEL FEMALE NUTS

1. Check flare and seat for defects.

2. Lubricate the connection.

3. Install hoses without twists.

4. Hand tighten until connection bottoms.

5. Using 2 wrenches to prevent twisting,

rotate the swivel nut 2 wrench flats

(1/3 turn).

6. For reassembly, follow the same

procedure but tighten only 1 wrench

flat (1/6 turn).

Drawbar Assembly

TIGHTENING PROCEDURE FOR

SWIVEL O-RING FITTINGS

1. Lubricate o-ring and install the fitting

until the metal washer which backs up

the o-ring contacts the face of the boss.

2. Then orient the fitting by turning

counterclockwise up to 1 turn.

3. Tighten the lock nut using 50-60 foot

pounds torque.