JUMO 706021 LOGOLINE 500d Line Recorder Data Sheet User Manual
Page 4
2010-06-21/00324162
Data Sheet 706021 (706000)
JUMO GmbH & Co. KG • 36035 Fulda, Germany
Page 4/11
Electrical data
Housing
Approvals/marks of conformity
Overrun/underrun
electronically limited to 0 — 100mm writing width
Chart speed
programmable in the steps: 0, 5, 10, 20, 60, 120, 240, 300, 360, 600, 720, 1800, 3600,
7200mm/h; freely programmable in 1mm/h steps
Chart drive
by stepping motor and gearbox
Chart cassette
cassette for roll chart and fanfold chart (tear-off edge, chart-end switch)
Chart
overall width / writing width
pin spacing
visible chart length
overall length
roll or fanfold chart to DIN 16320
120mm / 100mm
110mm
roll chart: 60mm; fanfold chart: 30 — 60mm
roll chart: 16m or 32m; fanfold chart: 15.6m
Supply
110 — 240V AC 48 — 63Hz or 20 — 53V AC/DC 48 — 63Hz
Electrical safety
Test voltages (type test)
- Mains supply to measurement circuit
- Mains supply to housing
- Between measurement circuits
- Measurement circuits to housing
- Electrical isolation between
the analog inputs
to EN 61010, Part 1 of March 1994
overvoltage category II, pollution degree 2
AC: 3.7kV 50Hz, 1min; AC/DC: 510V 50Hz, 1min
AC: 2.3kV 50Hz, 1min; AC/DC: 510V 50Hz, 1min
510V 50Hz, 1min
510V 50 Hz, 1min
up to 30V AC and 50V DC
Supply voltage error
less than 0.1% of range span
Power consumption
35VA max.
Data back-up
more than 4 years by lithium battery in RAM, or 2 days by storage capacitor at 15 — 25°C
ambient temperature. Additional back-up in EEPROM.
Electrical connection
at the back through screw-clamp connectors,
max. conductor cross-section 2.5mm
2
or 2x 1.5mm
2
with cable ferrules,
setup connector at the front behind the flip-up dot-matrix display
EMC
- Interference emission
- Immunity to interference
EN 61326-1
Class B
to industrial requirements
Housing type
Housing door
Housing for flush-panel mounting to IEC 61554, galvanized steel
zinc die-casting
Transport mechanism
in corrosion-resistant chrome-nickel steel
Chart cassette
in plastic (polycarbonate)
Bezel size
144mm x 144mm
Mounting depth
227mm
Panel cut-out
138
+1.0
mm x 138
+1.0
mm
Housing mounting
in a control panel to DIN 43834
Ambient temperature range
-10 to +50°C
Ambient temperature error
0.3% per 10°C
Storage temperature range
-20 to +70°C
Climatic conditions
75% max. rel. humidity, no condensation
Operating position
NL 90 ± 30, DIN 16257 (vertical)
Protection
to EN 60529 Category 2,
front IP54 (IP65 with extra code IP65); rear IP20
Weight
3.2kg max.
Mark of
conformity
Testing
laboratory
Certificates /
certification numbers
Test basis
valid for
c UL us
Underwriters
Laboratories
E 201387
UL 3111-1
CAN/CSA C22.2 No. 1010.1-92
the flush-mounted instrument;
not in conjunction with any hou-
sing extra code