beautypg.com

Safety temperature limiter stb – JUMO 701150 14597 safetyM STB/STW - Safety Temperature Limiter and Safety Temperature Monitor Data Sheet User Manual

Page 10

background image

Page 10/14

Data Sheet 701150

2012-07-01/00540116

JUMO GmbH & Co. KG
Delivery address: Mackenrodtstraße 14

36039 Fulda, Germany

Postal address:

36035 Fulda, Germany

Phone:

+49 661 6003-0

Fax:

+49 661 6003-607

E-mail:

[email protected]

Internet:

www.jumo.net

JUMO Instrument Co. Ltd.
JUMO House
Temple Bank, Riverway
Harlow, Essex CM20 2DY, UK
Phone: +44 1279 635533
Fax:

+44 1279 635262

E-mail:

[email protected]

Internet: www.jumo.co.uk

JUMO Process Control, Inc.
8 Technology Boulevard
Canastota, NY 13032, USA
Phone: 315-697-5866

1-800-554-JUMO

Fax:

315-697-5867

E-mail:

[email protected]

Internet: www.jumousa.com

Probes for water and oil

Probes for water, oil, and air

Safety control and regulating devices

Safety temperature monitor STW

1

The safety temperature monitor is a device that is automatically reset when activated once the sensor temperature has fallen below or risen
above the set limit value by an amount equal to the switching differential. Possible settings: monitoring for limit value overrange or underrange.

Mode of operations:
Minimum requirements: 2B, 2K, 2P
Additional requirements: 2N, 2D

Safety temperature limiter STB

1

The safety temperature limiter is a device that is permanently locked after responding.
Manual reset using the RESET key is possible once the probe temperature has fallen below / has exceeded the limit value by the amount of the
switching differential. Possible settings: monitoring for overrange or underrange.

Mode of operations:
Minimum requirements: 2B, 2J, 2V, 2K, 2P and adjustable with special tools
Additional requirements: 2N, 2F, 2D

1.

For more detailed explanation, see DIN EN 14 597.

Note:

The probes described in data sheets 901006 and 902006 are also certified for the Pressure Equipment Directive

Note: Because of the high response accuracy, only use thermowells (pockets) that are included in the scope of delivery.

Actual type designation

Old type
designation

Probe type

Temperature range

Nom. length mm

P

rocess connection

RTD temperature probe Data Sheet 90.2006

902006/53-505-2003-1-12-190-815/000

90D239-F03

2 x Pt100

-40 ... +400 °C

190

902006/53-507-2003-1-12-100-815/000

90.239-F02

2 x Pt100
(arranged one
below the other
in protection tube)

-40 ... +480 °C

100

902006/53-507-2003-1-12-160-815/000

90.239-F12

160

902006/53-507-2003-1-12-190-815/000

190

902006/53-507-2003-1-12-220-815/000

90.239-F22

220

902006/53-507-1003-1-12-100-815/000

90.239-F01

1 x Pt100

-40 ... +480 °C

100

weld-in sleeve

902006/53-507-1003-1-12-160-815/000

90.239-F11

160

902006/53-507-1003-1-12-220-815/000

90.239-F21

220

902006/53-505-1003-1-12-190-815/000

90.239-F03

1 x Pt100

-40 ... +400 °C

190

902006/53-505-3003-1-12-100-815/000

90.239-F07

3 x Pt100

-40 ... +400 °C

100

902006/53-505-3003-1-12-160-815/000

90.239-F17

160

902006/53-505-3003-1-12-220-815/000

90.239-F27

220

902006/40-226-1003-1-12-220-815/000

90.280-F30

1 x Pt100

-170 ... +480°C

220

weld-in sleeve

902006/40-226-1003-1-12-160-815/000

90.280-F31

160

902006/40-226-1003-1-12-100-815/000

90.280-F32

100

Thermocouples Data Sheet 90.1006

901006/53-543-1042-12-220-815/000

90.111-F01

1 x Fe-CuNi Type „L“

-35 ... 480°C

220

weld-in sleeve

901006/53-543-2042-12-220-815/000

90.111-F02

2 x Fe-CuNi Type „L“

220

Note: Because of the high response accuracy, the use of thermowells (pockets) is not admissible.

Actual type designation

Old type
designation

Probe type

Temperature range

Install. length mm

P

rocess connection

RTD temperature probe Data Sheet 90.2006

90.2006/10-390-1003-1-8-250-104/000

90.210-F95

1 x Pt100

max. 300°C

250

Thermocouples Data Sheet 90.1006

901006/45-551-2043-2-xxxx-11-xxxx

2 x NiCr-Ni, Typ

E „K“

max. 1

150°C

50...2000