5 trip point object – INFICON SKY CDGxxxD (DeviceNet) User Manual
Page 27
![background image](/manuals/562595/27/background.png)
tira51e1 (2009-01) CDGxxxD.cp
27
Class Code 35
h
= 53
d
The Trip Point Object models the action of trip points (two relays) of the CDG
(corresponding to physical outputs) (Discrete Output Object). A trip point value,
designated as a high or low trip point, is compared to the specified source value.
This trip point is intended to be used as a process control indicator.
Attribute ID Access
rule
Name
DeviceNet
data type
Description of attribute
1
Get
Revision
UINT
Revision of this object. Note: All class definitions
are required to include this class attribute.
2 Get Max
instance
UINT
Maximum instance number of an object currently
created in this class level of the device.
Attribute
ID
Access rule NV/
V
Name
DeviceNet
data type
Description of attribute
Semantics of values
5 Set
NV
Low
trip
point
INT or based
data type
attribute
Defines the value at or be-
low which a trip point con-
dition will occur.
→ "Semantics" section below
[default] = 0
6 Get
NV
Low
trip
enable
BOOL
Enables the low trip point
setting.
[default] = 0
7
Get
V Status
BOOL
State of this object
instance.
0 = trip point condition does not exist
(unasserted)
1 = trip point condition exists
(asserted)
10 Set
NV
Hysteresis
Same
as
high/low point
data type
Determines the amount by
which the input must re-
cover to clear a trip point
condition.
→ "Semantics" section
[default] = 0
12 Get
NV
Destination
Packed
EPATH
Specifies the path of the
destination attribute whose
value will be set by output.
Path to attribute 3 of Instance 1 or 2
of DOP Object.
13
Get
V Output
BOOL
Output of the object the
value of which is sent to
destination.
= Status of the relay
14 Get
NV
Source
Packed
EPATH
Specifies the path of the
source attribute whose
value is retrieved for Input.
Path to attribute 6 of instance 1 of S-
analog sensor object
15
Get
V Input
INT or speci-
fied by data
type
Input to the object whose
value is retrieved from
source.
Value of attribute 6 of instance 1 of S-
analog sensor object
16 Get
NV
Data
units
ENGUNITS
Units of input, trip point.
17 Get
NV
Data
type
USINT Data type of input.
[default] = INT
101 Set
NV
Percentage
of ATM
REAL
Multiplier for ATM control.
If high trip point enabled, this value
will be multiplied with pressure value
from S-Analog sensor instance 2
(ATM sensor) copied into trip point
high
102 Get
V
High
trip
point
INT or based
data type
attribute
Defines the value at or
above which a trip point
condition will occur.
[default] = 0
103 Get
NV
High
trip
enable
BOOL
Enables the high trip point
setting.
[default] = enabled
4.5 Trip Point Object
4.5.1 Class Attributes
4.5.2 Instance Attributes of
Trip Point Objects
Instance 1 & 2