29 getminproc – INFICON XTC/3 Thin Film Deposition Controller Communications Library Operating Manual User Manual
Page 59

1 - 45
IP
N 07
4-
45
4-
P1
B
XTC/3 Communications Library Operating Manual
1.3.2.29 getMinProc
int getMinProc (XTC3AllData *val, char* ErrMsg, unsigned short *len, BOOL 
TCP);
Description
This function is used for downloading all the instrument parameters without 
process layer lists and process names, which are:
General = XTC3_MAX_GEN_PARAM x 4 bytes
Film = NUM_OF_FILMS x MAX_FILM_PARAM x 4 bytes
IOMap = (NUM_OF_RELAYS + NUM_OF_TTLs + 
XTC3_NUM_OF_INPUTS) bytes
All Film Names (XTC/3M only): NUM_OF_FILMS x (up to 
XTC3_TITLE_LENGTH, null terminator included)
NOTE: See command UB2 and QB2 in the User’s Guide document.
The whole packet amounts to a maximum of XTC3_ALL_SIZE bytes.
Arguments
XTC3AllData* val:
This structure is filled with the instrument parameters as described above, 
which amounts to a maximum of XTC3_ALL_SIZE bytes. The variable 
m_Length is a 2 byte short that represents the length of data being 
marshaled in the array val->m_Data.
char* ErrMsg
unsigned short *len
BOOL TCP
- TGF10 Tracer Gas Filler (36 pages)
 - Sensistor ILS500 F Leak Detection Filler (90 pages)
 - T-Guard Leak Detection Sensor (85 pages)
 - T-Guard Leak Detection Sensor Interface description (40 pages)
 - Sensistor ISH2000P Hydrogen Leak Detector, Panel Model (51 pages)
 - Sensistor ISH2000 HySpeed Hydrogen Leak Detector (54 pages)
 - LDS3000 Modular Leak Detector (52 pages)
 - LDS3000 Modular Leak Detector Interface description (56 pages)
 - BM1000 Bus module (14 pages)
 - I/O1000 I/O module (18 pages)
 - CU1000 Control unit (24 pages)
 - Helium Leak Detector Modul1000 (130 pages)
 - Helium Leak Detector Modul1000 Interface description (40 pages)
 - UL5000 Dry Helium Leak Detector (108 pages)
 - UL5000 Dry Helium Leak Detector Interface description (14 pages)
 - UL1000 Fab Dry Helium Leak Detector (119 pages)
 - HLD6000 Refrigerant Leak Detector (76 pages)
 - HLD6000 Refrigerant Leak Detector Interface Description (40 pages)
 - IO1000 I/O module (18 pages)
 - Ecotec E3000 Multigas-Sniffer-Leak Detector (92 pages)
 - Ecotec E3000 Multigas-Sniffer-Leak Detector Interface description (36 pages)
 - Sensistor XRS9012 Hydrogen Leak Detector User Manual (28 pages)
 - Sensistor XRS9012 Hydrogen Leak Detector Maintenance manual (14 pages)
 - Extrima Ex-certified Hydrogen Leak Detector (62 pages)
 - Sensistor ILS500 Leak Detection System (107 pages)
 - Sensistor ISH2000 Hydrogen Leak Detector (58 pages)
 - Sensistor ISH2000 Hydrogen Leak Detector (108 pages)
 - Sensistor Sentrac Hydrogen Leak Detector (86 pages)
 - Protec P3000(XL) Helium Leak Detector (132 pages)
 - Pilot Plus Vacuum Gauge (2 pages)
 - CO Check Carbon Monoxide Meter (2 pages)
 - GAS-Mate Combustible Gas Leak Detector (12 pages)
 - Whisper Ultrasonic Leak Detector (8 pages)
 - Vortex AC Refrigerant Recovery Machine 115V (20 pages)
 - Vortex AC Refrigerant Recovery Machine 230V (16 pages)
 - Wey-TEK Refrigerant Charging Scale & Optional Charging Module (44 pages)
 - Wey-TEK Refrigerant Charging Scale & Optional Charging Module (2 pages)
 - D-TEK CO2 Refrigerant Leak Detector (12 pages)
 - TEK-Mate Refrigerant Leak Detector (12 pages)
 - Compass Refrigerant Leak Detector (12 pages)
 - D-TEK Select Refrigerant Leak Detector (12 pages)
 - Explorer Portable Gas Chromatograph (369 pages)
 - MicroFID II Portable Flame Ionization Detector (89 pages)
 - DataFID Portable Flame Ionization Detector for Landfill Emissions Monitoring (91 pages)
 - Hydrostik Hydrogen Fuel Cylinder Installation (7 pages)
 