3 gethellotwo – INFICON XTC/3 Thin Film Deposition Controller Communications Library Operating Manual User Manual
Page 25
1 - 11
IP
N 07
4-
45
4-
P1
B
XTC/3 Communications Library Operating Manual
1.3.2.3 getHelloTwo
int getHelloTwo (XTC3HelloData *val, char* ErrMsg, unsigned short *len, BOOL
TCP);
Description:
This function gets the Structure Number, Compatiblity Number, Range Number,
and Unit Type (XTC/3M vs XTC/3S).
Arguments:
XTC3HelloData *val
This 16 byte structure will hold the 4 integers described above, in that order,
sent by the XTC/3 instrument.
char* ErrMsg
unsigned short *len
BOOL TCP
Example:
#include "XTC3Lib.h"
void main()
{
if(StartSocket()==0)
printf("Socket could not be initialized.");
if(!ConnectSocket("10.211.70.209"))
printf("Socket could not be connected!");
char ErrStr[256];
unsigned short length = 0;
memset(ErrStr,0,256);
XTC3HelloData val;
BOOL TCP = TRUE; // TCP/IP comm.
getHelloTwo (&val, ErrMsg, length, TCP);
if(*ErrStr == 0)
{
printf("Data Transfer successful\n");
printf("Structure Number: %d\n"
"Compatibility Number: %d\n"
" Range Number: %d\n"
" Unit Type: %d\n",
val.m_Data[0], val.m_Data[1], val.m_Data[2],
val.m_Data[3]);
}
else
printf(ErrStr);
CloseSocket();
}
- TGF10 Tracer Gas Filler (36 pages)
- Sensistor ILS500 F Leak Detection Filler (90 pages)
- T-Guard Leak Detection Sensor (85 pages)
- T-Guard Leak Detection Sensor Interface description (40 pages)
- Sensistor ISH2000P Hydrogen Leak Detector, Panel Model (51 pages)
- Sensistor ISH2000 HySpeed Hydrogen Leak Detector (54 pages)
- LDS3000 Modular Leak Detector (52 pages)
- LDS3000 Modular Leak Detector Interface description (56 pages)
- BM1000 Bus module (14 pages)
- I/O1000 I/O module (18 pages)
- CU1000 Control unit (24 pages)
- Helium Leak Detector Modul1000 (130 pages)
- Helium Leak Detector Modul1000 Interface description (40 pages)
- UL5000 Dry Helium Leak Detector (108 pages)
- UL5000 Dry Helium Leak Detector Interface description (14 pages)
- UL1000 Fab Dry Helium Leak Detector (119 pages)
- HLD6000 Refrigerant Leak Detector (76 pages)
- HLD6000 Refrigerant Leak Detector Interface Description (40 pages)
- IO1000 I/O module (18 pages)
- Ecotec E3000 Multigas-Sniffer-Leak Detector (92 pages)
- Ecotec E3000 Multigas-Sniffer-Leak Detector Interface description (36 pages)
- Sensistor XRS9012 Hydrogen Leak Detector User Manual (28 pages)
- Sensistor XRS9012 Hydrogen Leak Detector Maintenance manual (14 pages)
- Extrima Ex-certified Hydrogen Leak Detector (62 pages)
- Sensistor ILS500 Leak Detection System (107 pages)
- Sensistor ISH2000 Hydrogen Leak Detector (58 pages)
- Sensistor ISH2000 Hydrogen Leak Detector (108 pages)
- Sensistor Sentrac Hydrogen Leak Detector (86 pages)
- Protec P3000(XL) Helium Leak Detector (132 pages)
- Pilot Plus Vacuum Gauge (2 pages)
- CO Check Carbon Monoxide Meter (2 pages)
- GAS-Mate Combustible Gas Leak Detector (12 pages)
- Whisper Ultrasonic Leak Detector (8 pages)
- Vortex AC Refrigerant Recovery Machine 115V (20 pages)
- Vortex AC Refrigerant Recovery Machine 230V (16 pages)
- Wey-TEK Refrigerant Charging Scale & Optional Charging Module (2 pages)
- Wey-TEK Refrigerant Charging Scale & Optional Charging Module (44 pages)
- D-TEK CO2 Refrigerant Leak Detector (12 pages)
- TEK-Mate Refrigerant Leak Detector (12 pages)
- Compass Refrigerant Leak Detector (12 pages)
- D-TEK Select Refrigerant Leak Detector (12 pages)
- Explorer Portable Gas Chromatograph (369 pages)
- MicroFID II Portable Flame Ionization Detector (89 pages)
- DataFID Portable Flame Ionization Detector for Landfill Emissions Monitoring (91 pages)
- Hydrostik Hydrogen Fuel Cylinder Installation (7 pages)