beautypg.com

Flint & Walling 4 (10 cm) Stainless Commander S Series User Manual

Page 8

background image

14

Copyright © 2014 Flint & Walling. All rights reserved.

15

Copyright © 2014 Flint & Walling. All rights reserved.

ElECTRICAl HOOKuP FROM THE HOuSE TO PuMP ANd PRESSuRE TANK

2. Remove cover from pressure switch and screw

the switch into the 1/4 in. opening on the top of

the pipe tee. (

Fig. 2)

3. Thread the cable from the house electrical service

through one of the holes in the side of the pressure

switch and tighten down the electric wire strain

relief.

CAuTION: Do not crush wire. (Fig. 3)

4. Connect the two wires from the house electrical

service to the outside pressure switch terminals

(L1 and L4). (

Fig. 4)

5. Thread the cable from the pump through the

remaining hole in the side of the pressure switch

and tighten down the electric wire strain relief.

CAuTION: Do not crush wire.

2

L4

L1

L4

L1

IL1162

L4

L1

Strain Relief

3

4

IL1165

5

ElECTRICAl HOOKuP FROM THE HOuSE TO PuMP ANd PRESSuRE TANK

6. Connect the two wires from the pump to the

inside pressure switch terminals (L2 and L3).

(

Fig. 6)

7. Connect green ground wires from the pump

cable and the house electric cable to the two

ground green screws on base of pressure switch.

Replace switch cover. (

Fig 7)

L3

L2

IL1167

L2

L3

6

Ground Screws

From

Pump

From

Power Source

7

For - 3-wire Pumps - Control box Is Required.

wARNING: This equipment is intended for installation by a technically qualified electrician. Failure to

install it in compliance with national and local electrical codes may result in electrical shock or fire hazard,

unsatisfactory performance, and equipment failure.

wARNING: Always disconnect power source before working on or near the pump, its connected load

and wiring. If the power disconnect is out of sight, lock it in the open position and tag to prevent unexpected

application of power.
NOTE: 3-wire pumps require a control box (See chart on page 6).

1. Determine proper voltage from breaker box to

pressure switch. (

Fig. 1)

IL1170

1