beautypg.com

Operating instructions, External pneumatic operated connector, Fastest, inc. product warranty – FasTest ML Series User Manual

Page 2

background image

OPERATING INSTRUCTIONS

www.fastestinc.com

Roseville, MN
Ph 1-800-444-2373
Fax 651-645-7390

WP090 9/30/2010

“ME001” EXPLODED VIEW

FOR REFERENCE

ME001

CONNECTOR

ML001

CONNECTOR

2. Main seal o-ring is held in the seal casing by friction fit. Remove old o-ring and

replace with a new one.












3. Place spring into housing up against the piston.
4. Thread seal casing into housing. Wrench tighten to prevent loosening.


ME001 Connector Seal Range

Changing the seal casing assembly allows the user to have one ME001 body seal the
entire .030” to .130” sealing range. The MES Replacement Seal Sets are list on the parts
list. Installation is similar to the replacement seal installation except that the entire seal
casing assembly (seal casing and Viton o-ring) is replaced.

Installation of Seals ML001:

To Replace Seal

1. Unscrew and remove seal casing. Wrench flats provide for easy removal.










2. Main seal o-ring is held in the piston by a recessed groove. Remove old o-ring by

sliding it over the end of the piston and replace with a new one.









3. Place spring into housing up against the piston.
4. Thread seal casing into housing. Wrench tighten to prevent loosening.


Connector Maintenance:

• A daily, weekly and periodic inspection of the connector by competent person is
recommended.

• Lubricate connector on regular intervals. Petroleum jelly is recommended but care
should be taken to verify the lubricant is compatible with the application.

• User must establish a regular interval for maintenance as determined by the user
media and operational environment.

• Inspection should include damage to the body missing or loose components, leak
tightness, ease of operation, sufficient lubrication, wear, dirt accumulation and
damage.

• Use only original FasTest spare parts that are designed for the application and are
subject to strict quality control. See warranty.












FasTest, Inc. Product Warranty

FasTest, Inc. warrants its products against defects of workmanship and/or material for 12
months from the date of the sale by FasTest, Inc. This warranty is void if the product is
misused, tampered with or used in a manner that is not in accordance with FasTest, Inc.
recommendations and/or instructions. FasTest, Inc. is not liable for consequential or other
damages including, but not limited to, loss, damage, personal injury, or any other expense
directly or indirectly arising from the use of or inability to use its products either separately or in
combination with other products. ALL OTHER WARRANTIES EXPRESSED OR IMPLIED,
WHETHER ORAL OR WRITTEN, INCLUDING BUT NOT LIMITED TO WARRANTIES OR
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ARE EXPRESSLY
EXCLUDED.
Remedy under this warranty is limited to replacement of the product or an account credit in the
amount of the original selling price, at the option on FasTest, Inc. All allegedly defective
products must be returned prepaid transportation to FasTest, Inc. along with information
describing the products performance, unless disposition in the field is authorized in writing by
FasTest, Inc.

ME001 & ML001 Mini Connector

External Pneumatic Operated Connector.

DESCRIPTION: Operation and Seal Installation


















Please thoroughly read and understand each of the following four steps before
operating the connector. The use of pressurized media for sealing, testing and
filling requires a thorough understanding of the FasTest ME/ML Operating
Instructions.

1.

Attachment of Pilot Pressure and Test Media Supply Lines

2.

Mounting Dimensions of Connector

3.

Connector Operating Instructions

4.

Installation of Seals

• The connector is designed to mate with a specific application. Verify the application

prior to the introduction of pressure or processing.

• Use only in a safe environment.
• Connectors are NOT designed for permanent connections and are for temporary

connections only.

• Maximum rated test pressure for standard ME models is 500 psi. DO NOT EXCEED

pressure rating as marked on connector or corresponding literature. Consult your
FasTest

representative with other requirements.

FasTest

ME & ML Pneumatic Operated Connectors are designed for use

in SECURED CONDITIONS ONLY.

MAIN SEAL O-RING

SPRING

WRENCH

FLATS

ccw

SEAL

CASING

MAIN SEAL O-RING

This manual is related to the following products: