beautypg.com

2 remote site – EZWatch CMS software for TurboView User Manual

Page 72

background image

72

Save Option: allow user to select Drive(C, D) and folder to save data.

Choose ‘OK’ to confirm the setting.

8.2.2 Remote

Site

This menu is for Network setup.

Make CMS IP address and Port coincide with DVR.

Remote Site Connection Setup

-

Site Name: input DVR site name to be displayed on the right-hand side of DVR icon. Please note that this name has

nothing to do with the ID registered in DVR. User may create a name that is fairly easy to distinguish.

-

IP Address/Domain Name: input IP address or Domain Name of DVR (check with SETUP>DEVICES>Network in DVR).

-

Command Port: input Administrator’s number among port numbers set in DVR (check with SETUP>DEVICES>Network in

DVR).

-

Stream Port: INPUT Video/Audio number among port numbers set in DVR (check with SETUP>DEVICES>Network in

DVR).

-

Re-connect when abnormal disconnected: When the CMS has abnormally disconnected, it automatically verifies the

network condition, then tries reconnecting to designated site.

Scan DVR

-

This function automatically detects and registers units currently connected to local networks.

-

Click “Scan DVR”, then following will pop up.