2 what operating states are available, What operating states are available – EUCHNER FSA Light User Manual
Page 14

Manual EKS Light and Light FSA
4.2 What operating states are available?
Depending on the application, various operating states can be selected. The differences between the different
operating states are explained briefly below. For more detailed information, please read the section for the
respective operating state.
Operating state
Description
0
General
Access is possible only to those installations for which exactly the same access code is set in the
DIP switch and on the Electronic-Key (1:1 allocation)
Forming user groups
A separate Electronic-Key must exist for each user group. Users belonging to several groups
therefore need several Electronic-Keys.
Forming installation groups
It is possible to form installation groups by setting the same access code on all installations of a
group.
1
General
The access code on the Electronic-Key can be structured so that several installations can be
covered with different access codes (1:n allocation). In this case, the matching of one bit position of
the bit pattern on the Electronic-Key and DIP switch is sufficient.
Forming user groups
The installations (installation groups) to which the user has access are defined on the user's
Electronic-Key.
A user can gain access to different installations (installation groups) with one Electronic-Key (e.g.
service Electronic-Key for maintenance personnel).
Forming installation groups
It is possible to form installation groups by setting the same access code on all installations of a
group.
Page 14/40
Subject to technical modifications
110845-04-03/12