3 operating state 0, Operating state 0 – EUCHNER FSA Light User Manual
Page 15

Manual EKS Light and Light FSA
4.3 Operating state 0
Application example:
Requirement:
There are three lathes D in a factory. They are to be operated by USER A and USER B.
USER B additionally is to be able to operate a milling machine F.
Solution with EKS Light:
A certain access code is set for all lathes D with the DIP switch on the read station (here: the binary value 0000000001).
The milling machine F is assigned the binary value 0000000011.
USER A receives an Electronic-Key with the access code 0000000001 (for lathes D).
USER B receives an Electronic-Key with the access code 0000000001 (for lathes D) and a second Electronic-Key with
the access code 0000000011 (for the milling machine F).
In addition to the access code, each user is assigned an access level with a value from 0 to 15.
110845-04-03/12
Subject to technical modifications
Page 15/40