8.4 Command overview
Description
Command message
Reply message
Program (write) Electronic-Key
TP (see section 8.3.1)
RF (see section 8.3.1)
Read Electronic-Key
(also read the serial number)
TL (see sections 8.3.2 and 8.3.3)
RL (see section 8.3.2)
or
RF (see section 8.3.2)
Reading the key status
Ek (see section 8.3.4) Ek (see section 8.3.4)
8.5 Status numbers
Value
Description
00
hex
No
error
02
hex
Electronic-Key not in the operating distance
03
hex
Parity bit error on read-only Electronic-Key
06
hex
Write process aborted. Start address or number of bytes is not a multiple of the block size 4
17
hex
Read attempt when the Electronic-Key adapter is set to read/write Electronic-Key and a read-only
Electronic-Key is inserted
18
hex
Read attempt when the Electronic-Key adapter is set to read-only Electronic-Key and a read/write
Electronic-Key is inserted
4x
hex
General Electronic-Key communication error (renewed write or read necessary)
50
hex
Write attempt despite enabled write protection
Page 38/40
Subject to technical modifications