4.4 DIP switch settings
The device has three DIP switches (S1, S2, S3).
DIP switch
Function
S1
(4-fold)
S1.1 … S1.4; write and read settings
S2
(8-fold)
S2.1 … S2.8; setting of a fixed DNS name (required only for special applications)
S3
(4-fold)
S3.1 …S3.4; settings for network connection and service
Information!
The settings are only applied when the power supply is switched on.
4.4.1 DIP switch S1
DIP
switch
Function
Factory setting
S1.1
ON = write protection for read/write Electronic-Key
OFF
S1.2 No
function
OFF
S1.3 No
function
OFF
S1.4 No
function
OFF
Information!
It is imperative that all DIP switches without a function (S1.2, S1.3 and S1.4) are set to OFF! In this
way problems with any functions added in the future will be avoided.
4.4.2 DIP switch S2
DNS
name
LSB
S2.1
S2.2
S2.3
S2.4
S2.5
S2.6
S2.7
MSB
S2.8
EKS000
OFF OFF OFF OFF OFF OFF OFF OFF
EKS001
ON OFF OFF OFF OFF OFF OFF
OFF
EKS002
OFF ON OFF OFF OFF OFF OFF OFF
EKS003
ON ON OFF OFF OFF OFF OFF OFF
… … … … … … … … …
EKS254
OFF ON ON ON ON ON ON ON
EKS255
ON ON ON ON ON ON ON ON
Information!
All DIP switches S2 are relevant only in conjunction with the Siemens SINUMERIK DHCP address
assignment (see section 6.1.1.3 Operation in the Siemens system network).