4.2 Technical data of Electronic-Key adapter
Attention!
All the electrical connections must either be isolated from the mains supply by a safety transformer
according to EN IEC 61558-2-6 with limited output voltage in the event of a fault, or by other equivalent
isolation measures.
General parameters
Value
Unit
min.
typ.
max.
Housing
Plastic (PA 6 GF30 gray)
Degree of protection according to EN 60529
IP 67 in installed condition
Ambient temperature at UB = 24 V DC
0
+ 55
°C
Mounting cut-out acc. to DIN 43700
33 x 68
mm
Connection for power supply
Plug-in screw terminal, 3-pole,
conductor cross-section 0.14 ... 1.5 mm²,
tightening torque 0.22 Nm
Operating voltage UB
(regulated, residual ripple < 5 %)
20 24 28
DC
V
Current consumption
150
mA
Interface, data transfer
Interface to the PC
Industrial Ethernet (IEEE 802.3)
Transfer protocol
TCP/IP
Data transfer rate (full duplex)
10/100
MBit/s
Data connection
1 x RJ45 socket
Data wire
2 x 2 twisted-pair copper cables, screened; min. category 5
Cable length
100
m
LED indicator
Green: "Ready" (in operation)
Yellow: "Electronic-Key active" *
red: "Error"
Parameters for the outputs LA and LB (version EKS FSA only)
Power supply for load U (LA, LB)
24
30
V
Switching current per output
1
50
mA
Number of actuations of the overload
protection
100
Output voltage high for U (LA, LB)
U x 0.9
U
V
Resistance in switched-on state
35
Ohm
Capacitance per output
2
nF
Additional capacitive load per output
1
µF
Utilization category according to AC-12
EN IEC 60947-5-2 AC-15
DC-12
DC-13
50 mA / 24 V
Difference time between the outputs**
(LB first)
200
ms
Connection screw terminals, 2 x 2-pole
0.14
1.5
mm²
* The LED illuminates yellow if there is a functional Electronic-Key in the Electronic-Key adapter.
** If access on the Ethernet interface takes place during the insertion or removal of the Electronic-Key,
the difference time can be more than 200 ms.