Operating Instructions Safety System CES-A-UBA-01/CES-A-UBA-01B

3

Correct Use

The Coded Electronic Safety switches series CES are safety devices for monitor-
ing movable safety guards.

In combination with a separating safety guard and the machine control, this safety
component prevents dangerous machine movements from occurring while the
safety guard is open. A stop command is triggered if the safety guard is opened
during the dangerous machine function.

Before safety switches are used, a risk assessment must be performed on the
machine in accordance with:

Ì

EN ISO 13489-1, Safety of machinery. Safety related parts of control systems.
General principles for design

Ì

EN ISO 14121-1, Safety of machinery. Risk assessment. Principles

Ì

IEC 62061, Safety of machinery – Functional safety of safety-related electrical,
electronic and programmable electronic control systems.

Correct use includes compliance with the relevant requirements for installation
and operation, in particular

Ì

EN ISO 13489-1, Safety of machinery. Safety related parts of control systems.
General principles for design

Ì

EN 1088, Safety of machinery. Interlocking devices associated with guards.
Principles for design and selection

Ì

EN 60204-1, Safety of machinery. Electrical equipment of machines. General
requirements

Ì

EN 60947-5-3 Specification for low-voltage switchgear and controlgear. Con-
trol circuit devices and switching elements. Requirements for proximity devices
with defined behaviour under fault conditions (PDF)

The following components can be connected to the evaluation unit CES-A-UBA...:

Ì

CES read heads

Ì

CEM read heads

Ì

CET read heads

For further information, refer to the operating instructions of the corresponding
component and to the following table Possible combinations for CES components.

Important!

Ì

The devices permit a safety-related stop function, initiated by a safety guard
according to Table 8 - DIN EN ISO 13849-1: 2008-12.

Ì

The safety-related function of the PDF is the opening of at least one
of the output contacts (13/14, 23/24) when the actuator is absent.

Ì

The user is responsible for safe integration of the device in a safe overall
system. For this purpose the overall system must be validated, e.g. in accor-
dance with EN ISO 13849-2.

Ì

The permissible operating parameters must be observed for correct use
(see Technical data).

Ì

If a product data sheet is included with the product, the information on the
data sheet applies in case of discrepancies with the operating instructions.

Ì

Only components may be used that are permissible in accordance with the
table below.