16
System Status Table
Operating mode
Actuator/door position
Safety outputs A and B
PLC
LED display
State
In-
Output
TST
OUT (status signal)
ERR
ST
A
TE (gr
een)
OUT (yellow)
ERROR (r
ed)
Normal operation
closed
on
N
1
0
Normal operation, door closed
open
off
N
0
0
Normal operation, door open
State indication
X
off
X
0
0
3 x +
Self-test after operating voltage is applied
Fault display
X
off
N
0
1
Device-internal component failure or
excessively high external interference (EMC)
Test operation
open
off
1
0
1
closed
off
1
0
1
External device test to "OPEN" and function of ERR output
with door closed
Key to symbols
N
0 Volt or not connected
1
24 Volt
0
0 Volt
LED is not lit
LED is lit
3 x +
LED flashes three times and then lights up continuously
X
Any state
Important!
If you cannot find the displayed device status in the system status table, this
indicates that there is an internal device fault. In this case, you should contact
the manufacturer.