Port setup options, Group ids, Contact closure (remote trigger connector) – ETC Eos Family Show Control User Manual
Page 9: Relay out (remote trigger connector), N o t e
Show Control Setup
7
Port Setup Options
Eos Ti, Gio, Ion, and Element have additional ports and connectors located on the rear panel for
show control. Additional setup options for these ports and connectors are in the
ECU>{Settings}>{Local I/O}.
Group IDs
Allows you to set the group number for the MIDI In and MIDI Out ports. Group numbers can be from
1-32. Default for both ports is 1.
Contact Closure (remote trigger connector)
Allows you to set the Group and Address In values for the remote trigger input on the back of your
console. The contact closure only reports on/off even though it is considered an analog input.
Relay Out (remote trigger connector)
Allows you to set the Group and Address In values for the remote trigger port on the back of your
console.
N o t e :
The local ports on Eos Ti, Gio, Ion, and Element consoles will not broadcast
information over the network and are only used in a local console system.
N o t e :
The contact closures require DC voltage, which is supplied by the console on pins
14+15. See the diagram below.
1
2
3
4
5
6
7
8
15
14
13
12
11
10
9
Ground
Ground
+ 12Vdc
+ 12Vdc
S1
S2
S3
S4
Relay Out, Normally Closed
Relay Out, Normally Open
Relay Out, Common
8 7 6 5 4 3 2 1
15 14 13 12 11 10 9
Remote Trigger
connector pinout