Stop, Resume, Fire – ETC Eos Family Show Control User Manual
Page 24: N o t e
22
Eos Family Show Control
Stop
When accompanying a MIDI “Stop” command, data for the following fields will result in the following
effects:
Resume
When accompanying a MIDI “Resume” command, data for the following fields will result in the
following effects:
Set
The “Set” command allows MSC to control potentiometers using both a numeric control number
(which specifies the potentiometer) and a data field (which controls the level: 0-100). Control values
are as follows
Accompanying any of these indications in the MSC data, a numeric value of 0-100 would set the
specified potentiometer to that level.
All other control values are ignored.
Fire
This command fires a macro. MSC supports macros 1 through 127 only. Therefore a numeric value
of 1 - 127 followed by 00 (in hex) would accompany this command.
Cue Data
Field
List Data
Field
Effect
Cue
List
Stops the specified cue & list (if running)
Cue
-
Stops the running cue from the default cue list
-
List
Stops the current cue from the specified list
-
-
Stops all cues
Cue Data
Field
List Data
Field
Effect
Cue
List
Resumes the specified cue & list (if stopped)
Cue
-
Resumes the specified cue in the default cue list
-
List
Resumes the current cue in the specified list
-
-
Resumes all stopped cues
Control
Value
Data Field
Indication
1-127
0-100
Submaster 1-127
128
0-100
Primary playback in
129
0-100
Primary playback out
510
0-100
Grandmaster
N o t e :
Levels transmitted must be followed with 00 (in hex) in order to be interpreted.