2. DC SOURCE OPTIONAL
Connect the DC power supply cable
to the VP+ and PR terminals of the main power connector.

Notes for connecting the DC power supply:

The source of the 0 ~ 88 VDC Power Supply must be isolated.

For the greatest immunity, it is highly recommended to use twisted and shielded

cables for the DC power supply cable. A 3-wire shielded cable should be used. The

gauge is determined by the actual current consumption of the motor.

Connect the cable shield to the closest ground connection near the power supply.

Connect the PE to the closest ground connection near the power supply.

Connect the PR to the closest ground connection near the power supply.

Before applying power, first verify the polarity of the connection.

Figure

3-4: Main Power DC Supply Connection Diagram

.11.3 Low power Auxiliary Supply (optional)

Notes for 12 ~ 95 VDC Auxiliary Supply connections:

The source of the 12 ~ 95 VDC Auxiliary Supply must be isolated from the main.

For safety reasons, connect the return (common) of the Auxiliary Supply source to the

closest ground near the Auxiliary Supply source.

Connect the cable shield to the closest ground near the Auxiliary Supply source.

Before applying power, first verify the polarity of the connection.

6.

Caution: Power to each Whistle and motor must come from the Main Supply