beautypg.com

Elkhart Brass 70133000 Electric Valves User Manual

Page 19

background image

19

Prior to assembly, all joint surfaces must be lubricated with a film of silicone oil or equivalent. All
cable/conduit entries must have a minimum protection degree of NEMA 4 or IP 66/68 (EN 60529).
Periodically remove any dust deposited on the cover. Use a damp cloth to remove the dust, thus avoiding the
creation of a static discharge.

V LUBRICATION

LUBRICATION INSPECTION

The actuator is lubricated for life, therefore, under normal working conditions it is not necessary to replace or
add lubricant.

If maintenance is performed, the recommended lubricant is AEROSHELL GREASE 7 or equivalent, for
ambient temperatures of -40°C to 70°C (-40°F to +158°F).


VI ACTUATOR SETTING AND CONFIGURATION

Before connecting power to the actuator, ensure that the power supply to be connected matches the voltage
indicated on the nameplate of the actuator. An incorrect power supply will cause permanent damage to the
electrical components. All calibration and settings are performed utilizing the control panel inside the controls
cover. To access the panel, remove the actuator cover as follows:


REMOVAL OF THE CONTROL UNIT COVER

Using a 5mm Allen key, loosen the four (4) bolts and remove the cover.

WARNING: Do not damage any sealing components or the flange of the cover or housing.

This manual is related to the following products: