5.3. Operating Procedure

5.3.1. Start Oven

1. Turn the yellow/red

DISCONNECT SWITCH

to ON.

2. Press the

POWER

to ON.

a. The

DOOR RELEASE

pushbutton will
illuminate. This means
the door can be opened.

b. For Optional Beacon Light-equipped Units Only: The amber (center)

beacon light will illuminate, indicating that the oven is ready to receive work
to be processed.

3. To open the oven door, press

DOOR RELEASE

while simultaneously pressing on the

door. The oven door will unlatch and open.

4. The heater is wired in series with the door switch. The door must be completely

closed and locked to activate the heater.


5.3.2. Working with Protocol Plus Operating Modes

Refer to the Protocol Plus Controller Owner’s Manual for specific information for
working with the controller.

5.3.3.

Sequence of Operation for Ovens Equipped with Optional Beacon
Light

1. After starting the oven (refer to Section 5.3.1), the Protocol Plus controller initializes.

a. The oven should be idle, empty, with the door closed and awaiting the next lot

for processing.

b. The Protocol Plus Controller should not be running a profile.

2. Open the oven door.


During the process cycle, DOOR
RELEASE will not be lit, meaning
that the oven door may not be
opened.

Figure 13. Power the Oven.