Table 5. mrc 5000 settings – Despatch Stackable LCC/LCD User Manual
Page 36

A
SSEMBLY
&
S
ETUP
Stackable LCC/LCD Oven
Owner’s Manual
36
Version 26
Copyright © 2010 by Despatch Industries.
All rights reserved. No part of the contents of this manual may be reproduced, copied or transmitted in any form or by any
means including graphic, electronic, or mechanical methods or photocopying, recording, or information storage and
retrieval systems without the written permission of Despatch Industries, unless for purchaser's personal use.
Table 5. MRC 5000 Settings.
Parameter Code
Degrees C
Degrees F
Inps
18
18
Icor
0
0
diSP
On
On
dPOS
0
0
EUU**
400
752
EUL**
0
32
ChUP
400
800*
ChLO
0
0
DFF
1
1
* Change 0-400 chart paper to 0-800 chart paper. Depending on the equipment used, 0-
600 paper may be used if the maximum temperature is 500 degrees F.
** These values must match the settings
sRetOutLo
and
RetOutHi
on the Protocol Plus
Control page. For example, if
RetOutLo
is 32,
EUL
must read 32.