Caution!
The HEPA filter must be installed so that unfiltered air cannot
leak past the unit. The HEPA gasket (white triangular gasket) is
generally in the downstream position and in contact with the
oven-sealing surface
In general, defer to installation instructions provided by the filter
manufacturer.
Termikfil 2000 Filter Installation Notes:
If a spacer is required for the gasket, place the spacer on the
opposite side to the HEPA gasket
If the Termikfil 2000 filter is mounted in a slide, do not rub
the filter on its gaskets
Any clamping device used must allow necessary and
sufficient pressure on the gaskets provide an airtight fit.
NOTE: Over tightening may damage the Termikfil 2000 filter.
Clamping recommendation: Clamp the Termikfil 2000 filter to
a residual HEPA gasket thickness of 4 mm (1/6 inch)
Refer to installation instructions provided by the filter
manufacturer for more specific installation notes.
1. Remove filter from carton
Sweep floor clear of nuts, bolts and other protrusions which
may damage the unit.
Do not drop or jar the filter carton.
a. Place carton on floor.
b. Tilt the carton on one corner. Handle the carton at opposing corners.
c. Remove sealing tape and fold back flaps of carton.
d. Gently upend the filter to place the exposed end of the filter on the floor. Do
not jar the filter.
e. Pull the carton from the filter unit. Be careful to not pull the filter from the
carton.