beautypg.com

25 string replacement example plain text, Tally dascom 2610 – Dascom 2600 User Guide User Manual

Page 87

background image

Tally Dascom 2610

74

When selecting one of the logical printers under the Description column, the following page is

displayed:

In this example if the Enable checkbox is checked, the pre-string of “Beginning to print job”

followed by a CR/LF will print at the beginning of every job sent to this LPR Queue. At the

end of the print job, the message “End of job” with a formfeed will print. Unchecking the

Enable checkbox will not send the pre or post strings. The LPD Queue Name is the name of

the print queue that comes from the host. The Description can be changed by the user and

does not have to match the LPD Queue Name.

6.3.25 String Replacement Example Plain Text
Original Text / New Text

String Replacement Example Commands /\1B[8419t/\1B[4196t/

Control codes are entered with a back slash “\”.

In this example the Formlength of A4 (8419”/720) represented by “1B[8419t” is being

replaced by the string “1B[4196t” (4196”/720) which results in A5.

Multiple strings are separated by a semicolon “;”.