beautypg.com

Dascom T5040 User Guide User Manual

Page 71

background image

User Guide

Menu

63

Protocol

Ready/Busy

*

Xon/Xoff

Selects the type of protocol, i.e. a certain set of
rules and procedures for ensuring error-free
data exchanges between computer and prin-
ter. Details of the available protocols can be
found in the section

Serial attachment

characteristics

, page 131.

CTS

Valid

*

Invalid

Sets the signal CTS (Clear To Send) on or off.

If Parallel is selected

Parallel Bidir

On

*

Off

Sets the bidirectional data transfer
(IEEE1284): if set to on ECP is supported, if off
Nibble mode only is supported.

If RS232_2 is selected

3)

Baud rate 2

4800
9600
19200

*

38400

Selects the data transmission rate (baud rate)
(baud = bit per second).

Data bits 2

7
8

*

Selects the number of data bits per data byte.

Stop bits 2

1

*

2

Selects if one or two stop bits are used per
data byte.

Parity 2

Even
Odd
None

*

The parity test for received data bytes can be
selected. None causes transmission in both
directions without parity bit. If Even or Odd is
selected, the bytes are checked to ensure they
have even or odd parity.

Protocol 2

Ready/Busy

*

Xon/Xoff

Selects the type of protocol, i.e. a certain set of
rules and procedures for ensuring error-free
data exchanges between computer and prin-
ter. Details of the available protocols can be
found in the section

Supported protocols

,

page 131.

CTS 2

Valid

*

Invalid

Sets the signal CTS (Clear To Send) on or off.

MENU
EMULATION

Emulation type

Epson

* (USER1)

IBM Proprinter XL
Olivetti

* (USER2)

IBM 4722

Selects the emulation for the printer. For fur-
ther details refer to chapter

Emulations

,

page 109

T5023 Compatible

No

*

Yes

Selects if the printer is compatible to the T5023
printer or not.

1) Only in Epson and IBM emulation
2) Only if MSR-H is installed
3) Only for printer model with second serial interface

Parameter group

Parameter

Possible settings

Description