Troubleshooting guide – Condux APS75 Underground Pulling Trailer User Manual
Page 21

21
3.
9.
PROBLEM:
CAUSE:
SOLUTION:
The diesel engine starter
doesn’t work.
Burned fuse
Replace
Run down battery (Light on
Kohler Controller)
Recharge or replace
Disconnected contacts of the
ignition system / starter
Reconnect
Oxidised contacts of the
ignition system / starter
Clean or spray with a
suitable vaporiser
Starter out of order
Replace / Technical
assistance
Diesel engine doesn’t
work.
The ignition key not turned
to start position
Turn ignition key
clockwise to start
position and hold until
the engine starts
The glow plug indicator
light isn’t turned off (On
Kohler Controller)
Wait for the glow plug
indicator light to turn
off before starting
Fuel problem
Check the fuel level in
the tank
Check the fuel filter
Diesel engine turns
off when releasing the
ignition key.
Check of the engine oil
pressure
Add engine oil
Defective sensor–
check contacts /
replace
Engine anomaly –
technical assistance
Check of the engine cooling
liquid temperature
Add cooling liquid
Defective sensor–
check contacts /
replace
Engine anomaly –
technical assistance
The charge pressure
is lower than 24 bar –
340psi
Clogged hydraulic oil filter
Replace
Defective pump
Technical assistance
Diesel engine doesn’t
increase rpm
Disconnected accelerator
cable
Verify and if necessary
replace
Troubleshooting Guide