If water softeners are present in the home, Clarus Environmental

recommends the use of water and salt conservative models that are

installed and operated correctly. If you have questions about softeners,

contact the Water Quality Association at www.wqa.org. Contact factory

for installation details.

WATER SOFTENERS

AUTHORIZED MAINTENANCE PROVIDER

Your authorized maintenance provider will perform many system checks

and adjustments as needed during the maintenance inspection. Two

inspections per year will be made for a total of four inspections during

the initial service policy. Please see the Operation and Maintenance

section of this manual for further details.

Should there be any operational deficiencies with your Fusion

®

,

the maintenance provider will notify the owner in writing when the

deficiencies will be corrected. If the maintenance provider does not

correct the deficiencies or the service calls are not completed, please

contact Clarus Environmental at 1-800-928-7867.

ALARM CONDITION

If an alarm condition occurs, please check the air intake area around

the blower and make sure no debris blocks the blower intake. Remove

the air filter cap. Remove the filter and gently tap against your other

hand. If it is very clogged wash it in warm, soapy water and dry well

before replacing. Reassemble filter and cap on top of blower. Do

not attempt to remove the blower housing or any other parts from

the blower. If the blower is operating properly, there may be a high

water condition within the Fusion

®

. It may be necessary to discontinue

water use until the alarm condition has been resolved. If the buzzer

continues to sound or the red light stays on, please contact your

authorized Fusion

®

maintenance provider. The buzzer may be silenced

by toggling the black switch on the side of the alarm panel to “silence”.

The red beacon light will remain on until the problem has been

resolved.

Check the circuit breaker and make sure the blower circuit is on. Reset

the breaker switch if it has been tripped. If it continues to trip or the alarm

continues to remain on, contact your Fusion

®

maintenance provider.

POWER OUTAGE

Should you experience a power outage, the blower will not operate

and air (oxygen) will not be supplied to the Fusion

®

. If the blower

is off for more than 24 hours, the lack of fresh air will cause the

treatment efficiency to decrease. During a power outage, the

Fusion

®

will still allow effluent to flow, and will not create a backup

in the home. You may, however, have a pump or dose tank with

a pump on the outlet of the Fusion

®

, which requires power to pump

the effluent to the soil absorption field. If you have a system such

as this, please be aware of this condition and conserve water

accordingly.

FLOODING

If flooding of the Fusion

®

occurs and the blower

or the alarm panel is submerged, please disconnect power at the

circuit breaker. DO NOT try to reconnect power to either the blower

or alarm panel once it has been submerged. Immediately contact your

authorized Fusion

®

maintenance provider to inspect the Fusion

®

, the

blower, and the alarm panel. Your maintenance provider will repair or

replace the components as needed.

Fusion

®

Series systems are compact, efficient, and designed to be

installed in a typical residential/light commercial environment. The final

effluent leaving the system will typically be treated to the secondary

quality strength.

EFFLUENT QUALITY

INSPECTION AND MAINTENANCE FREQUENCY

Fusion

®

Series systems are to be inspected and maintained every six

months under normal usage. The inspection and maintenance are

only to be performed by personnel trained and authorized by Clarus

Environmental. A Maintenance & Service Report (CL0059) is to be

completed for each inspection and maintenance visit.

An extended maintenance policy is available for purchase from your

authorized Fusion

®

distributor. The extended maintenance policy will

include the same system checks, schedule, and adjustments as the

initial maintenance policy. Please contact your Fusion

®

distributor or

maintenance provider for further information regarding the extended

maintenance policy.

EXTENDED MAINTENANCE POLICY

The Fusion

®

system is designed to function even if wastewater does

not enter it for extended periods of time. The power to the blower must

remain on during this time for the system to function properly. Weekend

use will not harm the system as long as the blower is on. Should

seasonal use require a complete shut down of the property, then it is

recommended that the blower be turned off. It is important to start up the

system in advance of actual occupancy to allow for normal treatment to

resume. Please contact your authorized Fusion

®

maintenance provider

for further information concerning shut down and startup of the Fusion

®

.

You may also contact your maintenance provider for the shut down and

startup services.

INTERMITTENT USE