beautypg.com

Clarus Environmental Recirculating Media Filters User Manual

Page 7

background image

7

© Copyright 2011. All rights reserved.

The Clarus Environmental Recirculating Media Filter is designed as a secondary treatment device. It works in conjunction with the septic

tank (primary treatment) and the drain field (water disposal and final polishing) to provide excellent overall treatment of the onsite effluent.

Refer to the diagram below to see the overall flow of effluent through the system.

Section 2: Pump Discharge System Installation

Figure 3: Pump Discharge Media Filter System Flow Schematic

General System Installation Outline

1. Install septic tank.

2. Install drain line as required to septic tank.

3. Install dosing tank.

4. Install piping between septic tank and dosing tank.

5. Install dosing tank pump.

6. Install wiring from dosing pump to control panel.

7. Install media filter (see detailed instructions below).

8. Install force main from dosing tank to media filter.

9. Install media filter pump.

10. Install wiring from media filter pump to control panel.

11. Install return line from media filter to 80/20 pressure flow splitter.

12. Install 80/20 pressure flow splitter at highest point.

13. Install return line from 80/20 pressure flow splitter to dose tank.

14. Install drain line from 80/20 pressure flow splitter to drain field.

SK2097B

TO DISPOSAL FIELD

HOUSE

SEWER

20%

80%

PRESSURIZED FLOW

GRAVITY FLOW

SEPTIC

TANK

DOSE

TANK

MEDIA

FILTER

80/20

PRESSURE

FLOW

SPLITTER

W/PUMP

DISCHARGE

CLARUS TIMED

DOSING PANEL

80% RECIRCULATION

20% TO DRAIN

FIELD SYSTEM

80/20

PRESSURE

FLOW

SPLITTER

SEPTIC TANK

DOSE TANK

FORCE MAIN FROM DOSE

TANK TO MEDIA FILTER

SK2229