Clarus Environmental Recirculating Media Filters User Manual
Page 7
7
© Copyright 2011. All rights reserved.
The Clarus Environmental Recirculating Media Filter is designed as a secondary treatment device. It works in conjunction with the septic
tank (primary treatment) and the drain field (water disposal and final polishing) to provide excellent overall treatment of the onsite effluent.
Refer to the diagram below to see the overall flow of effluent through the system.
Section 2: Pump Discharge System Installation
Figure 3: Pump Discharge Media Filter System Flow Schematic
General System Installation Outline
1. Install septic tank.
2. Install drain line as required to septic tank.
3. Install dosing tank.
4. Install piping between septic tank and dosing tank.
5. Install dosing tank pump.
6. Install wiring from dosing pump to control panel.
7. Install media filter (see detailed instructions below).
8. Install force main from dosing tank to media filter.
9. Install media filter pump.
10. Install wiring from media filter pump to control panel.
11. Install return line from media filter to 80/20 pressure flow splitter.
12. Install 80/20 pressure flow splitter at highest point.
13. Install return line from 80/20 pressure flow splitter to dose tank.
14. Install drain line from 80/20 pressure flow splitter to drain field.
SK2097B
TO DISPOSAL FIELD
HOUSE
SEWER
20%
80%
PRESSURIZED FLOW
GRAVITY FLOW
SEPTIC
TANK
DOSE
TANK
MEDIA
FILTER
80/20
PRESSURE
FLOW
SPLITTER
W/PUMP
DISCHARGE
CLARUS TIMED
DOSING PANEL
80% RECIRCULATION
20% TO DRAIN
FIELD SYSTEM
80/20
PRESSURE
FLOW
SPLITTER
SEPTIC TANK
DOSE TANK
FORCE MAIN FROM DOSE
TANK TO MEDIA FILTER
SK2229