General preinstallation checklist – Clarus Environmental Recirculating Media Filters User Manual
Page 3
3
© Copyright 2011. All rights reserved.
This manual is divided into two installation sections. The first section covers the installation of a Recirculat-
ing Media Filter with gravity discharge. The second section covers the installation of a Recirculating Media
Filter with pump discharge. Be sure to follow the correct section for the proper instructions.
General Preinstallation Checklist
1. Inspect your recirculating Media Filter package. Occasionally
products are damaged during shipment. If the unit is
damaged, contact your dealer before using. Do Not remove
the test plugs in the pump switch cover nor the pump motor
housing.
2. Carefully read all literature provided to familiarize yourself
with specific details regarding installation and use. These
materials should be retained by the end user for future
reference.
3. Total septic system design is critical to the operation of the
system. A Licensed Professional Engineer or a professional
as prescribed in your local code should design ALL systems.
A site plan should be developed that includes the placement
and elevations of all components. If an engineer is not involved
with the system you are working on, Clarus Environmental
highly recommends that one be contacted to review the
installation. Clarus Environmental can provide technical
help and regional engineering services for system design
by calling Clarus Environmental at 1-877-244-9340.
4. Your Recirculating Media Filter kit contains most of the
components needed for installation. However the installing
contractor must provide a few items. Refer to the list below
for additional materials required.
Clarus Environmental Recirculating Media Filter Kit
Includes:
• Clarus Environmental patented WW1 septic tank effluent
filter
• Proven quality effluent pump(s)
• Factory assembled dose tank discharge assembly
• Factory assembled media filter distribution piping with
cleanouts
• Orifice shields
• Cleanout risers
• EPDM rubber liner
• Drain collection system for media filter
• 80/20 flow recirculation splitter
• Timed dosing control panel and switches
• Under liner protection blanket
Optional:
• Prewired conduit assembly and junction box (ordered
separately).
Contractor Provides:
• House sewer line
• Septic tank and dose tank
• All piping outside dose tank and media filter
• Drain field components
• Frame for media filter (treated 2x10s recommended)
• Media filter gravel
5. Most residential kits include a Zoeller model N153 pump.
This pump is 1/2 HP, 115V, single phase unit capable of
delivering the proper flow and head for most installations.
Verify which pump your system is engineered to use. Follow
the instructions in the pump box (FM0447) to install the
pump properly.
6. Check to be sure that your power source is capable of handling
the voltage requirement of the pump motor, as indicated on
the pump nameplate. Make sure the pump electrical supply
circuit is equipped with fuses or circuit breakers of proper
capacity. A separate branch circuit is recommended, sized
according to the “National Electrical Code” for the current
shown on the pump nameplate.
7. The installation of pumps with variable level float switches is
the responsibility of the installing party and care should be
taken that the tethered floats will not hang up on the pump
apparatus or pit peculiarities and is secured so that the pump
will operate properly.