beautypg.com

Barranca Diamond BD-2003E Pro Series Core Saw User Manual

Page 21

background image

21

WARNING

NOTE: If using a dry blade for operation, DO NOT connect the water pump.

NOTE: When using the re-circulation method, the water should be changed often for longer pump life.

NOTE: In order to avoid breaker tripping, a 20-amp circuit breaker should be used.

The Water Pump can be setup for operation in two ways: External water source or Re-circulation.

This is the preferred method of cooling.

Before powering or starting, check for damage that could prevent this equipment form proper operation

or performing its intended function. Check for binding and alignment of moving parts. Check for dam-

aged, broken or missing parts.

* The BD-2003E Pro Series is also available with a 50Hz motor.

1. Verify or remove the Drain Plug form the Water Pan.

2. Place the Water Pump in an external container.

3. Fill the external container until water completely covers the Water Pump suction.

1. If not installed, install the Drain Plug into the Water Pan.

2. Place the Water Pump in the back of the Water Pan.

3. Fill the Water Pan until water completely covers the Water Pump suction.

1. Verify the ON/OFF switch is in the OFF position.

2. Before connecting the BD-2003E to a power supply, be sure the voltage, cycle and phase of the

job site power source meet the requirements of the table below.

3. If using an extension power cord, make sure the length and wire gauge correspond to the

requirements.

4. Listed in the Table on Page 12. An extension power cord that is too small in wire gauge (diameter),

or too long in length, will cause the motor overheat and could cause premature failure.

5. DO NOT cover the motor vents as this could lead to motor overheating.

BD-2003 CORE SAW

OPERATION

8KW

120/240 Volts

66.7/33.3 Amps

Single Phase

WATER PUMP SETUP FOR OPERATION

EXTERNAL WATER SOURCE

RE-CIRCULATION

SETUP FOR OPERATION

PORTABLE GENERATOR

Voltage

230V

Cycle

60Hz

Phase

1-phase