Bd-2003 core saw safety – Barranca Diamond BD-2003E Pro Series Core Saw User Manual
Page 12
12
BD-2003 CORE SAW
SAFETY
WARNING
Use only extensions cords that are intended for outdoor use. These extension cords are identified
by a marking “Acceptable for use with outdoor appliances; store indoors while not in use.” Use only
extension cords having an electrical rating not less than the rating of the product. Do not use dam-
aged extension cords. Examine extension cords before using and replace if damaged. Do not abuse
extension cords and do not yank on any cord to disconnect. Keep cords away from heat and sharp
edges. Always disconnect the extension cord from the receptacle before disconnecting the product
from the extension cord.
WARNING
To reduce the risk of electrocution, keep all connections dry and off the ground. Do not touch the
plug with wet hands.
EXTENSION CORD LENGTH
Nameplate
Amperes
115V
25'
50'
75'
100'
150'
200'
250V
50'
100'
150'
200'
300'
400'
0 - 5
16
16
16
14
12
12
5.1 - 8
16
16
14
12
10
•
8.1 - 12
14
14
12
10
•
•
12.1 - 15
12
12
10
10
•
•
15.1 - 20
10
10
10
•
•
•
WARNING
Use of undersized extension cords result in low voltage to the motor that can result in motor burnout
and premature failure. MK Diamond warns that equipment returned to us showing signs of being run
in a low voltage condition, through the use of undersized extension cords,will be repaired or replaced
totally at the customer’s expense. There will be no warranty claim.
To choose the proper extension cord,
• Locate the length of extension cord needed in the table below.
• Once the proper length is found, move down the column to obtain the correct
AWG size required for that length of extension cord.
ON
(
(
)
)