3 logs, Refer to, For more details – 2N VoiceBlue Next v3.1 User Manual
Page 70: Subs. 4.3
70
4.3 LOGs
For the current LOG records see the
section
Gateway / Gateway control – LOG file
or use the AT&L AT command for Telnet sessions. The following list of LOG statuses is
universal and some LOGs may not be included in
:
2N VoiceBlue Next
®
Type
Text
Description
POWER
[Power on]
System switched on
[Power off]
System switched off
[Warm boot]
Restart of system, unknown cause
[Watchdog]
Restart of system by watchdog
[BKPT code]
CPU error: break code detected
[Stack error]
CPU error: stock integrity failure
[Divided by
zero]
CPU error: dividing by zero
[RETI code]
CPU error: illegal using of instruction reti
[NMI intr]
CPU error: wrong interrupt
[VOID intr]
CPU error: wrong interrupt
[Upgrade reset] Start of upgrade firmware procedure
[Software
reset]
Reset by AT commands (at&fres…)
INIT
Eeprom
Initialisation of eeprom (configuration)
Flash
Initialisation of flash memory (firmware)
HW–ERR
(##…address of chip, RD…read value/WR…expected
value)
Codec
##,RD/WR
Error in initialisation of codec on GSM,AUX board
COM2
#####,RD/WR
Error in initialisation of COM2 on AUX board
Duart
#####,RD/WR
Error in initialisation of serial controller on GSM board
Hscx
#####,RD/WR
Error in initialisation of HDLC controller on AUX board
Pri
#####,RD/WR
Error in initialisation of PRI controller
SYSERR
User stack
error!
SW error: stock integrity failure
BRDIN
#08 TYP STS
Board inserted (number of gsm board, type, status)
BRDOUT
#08 TYP STS
Board disconnected
BRDRES
#08 TYP STS
Reset the board by AT command