beautypg.com

3 logs, Refer to, For more details – 2N VoiceBlue Next v3.1 User Manual

Page 70: Subs. 4.3

background image

70

2N TELEKOMUNIKACE a.s., www.2n.cz

®

4.3 LOGs

For the current LOG records see the

section

Gateway / Gateway control – LOG file

or use the AT&L AT command for Telnet sessions. The following list of LOG statuses is

universal and some LOGs may not be included in

:

2N VoiceBlue Next

®

Type

Text

Description

POWER

[Power on]

System switched on

[Power off]

System switched off

[Warm boot]

Restart of system, unknown cause

[Watchdog]

Restart of system by watchdog

[BKPT code]

CPU error: break code detected

[Stack error]

CPU error: stock integrity failure

[Divided by
zero]

CPU error: dividing by zero

[RETI code]

CPU error: illegal using of instruction reti

[NMI intr]

CPU error: wrong interrupt

[VOID intr]

CPU error: wrong interrupt

[Upgrade reset] Start of upgrade firmware procedure

[Software
reset]

Reset by AT commands (at&fres…)

INIT

Eeprom

Initialisation of eeprom (configuration)

Flash

Initialisation of flash memory (firmware)

HW–ERR

(##…address of chip, RD…read value/WR…expected
value)

Codec
##,RD/WR

Error in initialisation of codec on GSM,AUX board

COM2
#####,RD/WR

Error in initialisation of COM2 on AUX board

Duart
#####,RD/WR

Error in initialisation of serial controller on GSM board

Hscx
#####,RD/WR

Error in initialisation of HDLC controller on AUX board

Pri
#####,RD/WR

Error in initialisation of PRI controller

SYSERR

User stack
error!

SW error: stock integrity failure

BRDIN

#08 TYP STS

Board inserted (number of gsm board, type, status)

BRDOUT

#08 TYP STS

Board disconnected

BRDRES

#08 TYP STS

Reset the board by AT command