2.1.5. Internal lines
Pulse #. The digit replacing the tone hash on pulse telephones.
Pulse *. The digit replacing the tone asterisk on pulse telephones.
Time for 1
st
dialling. Defines the maximum time waiting for the first number to
be dialled after phone is picked up. The line gets the engaged tone after this
time period has elapsed.
Time for further dialling. Defines the maximum time spent waiting for the next
number to be dialled from an internal line. After it has lapsed the engaged tone
is heard and the call is cancelled.
Crossing Time to failure loop. Defines the time period before the engaged
tone is sent following unsuccessful dialling. After the line goes to a fault loop.
Bad dial key protection. The time period for which the next digit dialled is
ignored after dialling the entire number. It serves to prevent inadvertent call
back after unsuccessful dialling.
Switching on lock. The time the intercom lock is fastened.
Regime supervisor is valid. The time period for which the supervisor services
can be called upon after logging in to the Supervisor service
Ticking after attach. The time for which a ticking can be heard on the call after
connecting. After this period the service cannot be disconnected from the call.
Back to forwarder. The time the PBX tries to get a connection after
reconnecting with a hung up line. After this time it carries on in getting a
connection but it also starts ringing back to the switcher.
Back to operator. If the target user does not pick up the phone in this period
the ringing goes back to the operator.
End of switching over. After this period the PBX considers the call as dead.
The caller is told this by a voice telling them that all lines are unavailable and
the call is cancelled.
Ringing of holding CO. The time between being notified by tinkling on an
internal line that an external call is on hold.
End of holding. The time limit for a temporarily held external line to be hung
up.
Time of back ringing. The time call back lasts for.
Length of alarm ringing. The time the alarm will ring after activating it on an
internal line.
Delay from front. The time when a new incoming call is not accepted after
having been hung up.
Increasing of DTMF resistant for DISA. Min. length of the DTMF sign that is
accepted in the DISA direct inward calling.
Increasing of DTMF resistant for VMail. Min. length of the DTMF sign that is
accepted in VoiceMail.
Trace key system phone L2
– enable writing of key system phone layer 2
events into LogSystem listings.
To read the data push the „dollar‟ button on the
main bar of the configuration tool while reading accounting data, for example.
Trace key system phone ringing
– enable writing of key system phone ringing
into LogSystem listings.
To read the data push the „dollar‟ button on the main
bar of the configuration tool while reading accounting data, for example.