Calibration descriptions -27 – JLG M600 Service Manual User Manual
Page 193
SECTION 6 - JLG CONTROL SYSTEM
3121813
– JLG Lift –
6-27
Table 6-8. Calibration Descriptions
CALIBRATIONS
Not available at password level 2; can be viewed but not changed at level 1
CONTROLLER CALS
TEMPERATURE …
Displays/adjusts heatsink temperature calibration
The setting should not be altered from that set during manufacture
TRACTION I …
Displays/adjusts traction motor current calibration
The setting should not be altered from that set during manufacture
PUMP I …
Displays/adjusts pump motor current calibration
The setting should not be altered from that set during manufacture
TILTdelayIN …
Displays/adjusts how long the tilt sensor must indicate a tilted condition before it is registered
The setting should be adjusted to optimize controller response to a sudden tilt, while minimizing spurious tilt indica-
tions during acceleration & deceleration
TILTdelayOUT …
Displays/adjusts how long the tilt sensor must indicate a not-tilted condition before it is registered
The setting should be adjusted to optimize controller response to a sudden tilt, while minimizing spurious tilt indica-
tions during acceleration & deceleration
MACHINE CALS
BRAKE
Displays/adjusts brake release speed
The setting should be adjusted to release the brakes in the desired time, with minimal effect on other boom functions
PUMP@0%
Displays/adjusts minimum pump%on
The setting should be adjusted to minimize speed variations when functions are used individually and in combina-
tions
PUMP@100%
Displays/adjusts maximum pump%on
The setting should be adjusted to minimize speed variations when functions are used individually and in combina-
tions
Vflow@0%
Displays/adjusts minimum flow control proportional valve%on
Vflow@100%
Displays/adjusts maximum flow control proportional valve%on
Vlift@0%
Displays/adjusts minimum lift proportional valve%on
Vlift@100%
Displays/adjusts maximum lift proportional valve%on
Vswing@0%
Displays/adjusts minimum swing proportional valve%on
Vswing@100%
Displays/adjusts maximum swing proportional valve%on
SPEEDprop1 …
Displays/adjusts speed control PID algorithm proportional term in traction mode
The setting should be adjusted to optimize speed control
SPEEDprop2 …
Displays/adjusts speed control PID algorithm proportional term in plugging mode
The setting should be adjusted to optimize speed control
SPEEDint …
Displays/adjusts speed control PID algorithm integral term in traction & plugging mode
The setting should be adjusted to optimize speed control
PLUGmax …
Displays/adjusts maximum plugging current
The setting should be adjusted to ensure that the vehicle can be safely stopped when being driven down maximum
grade