JLG M600 Service Manual User Manual
Page 192
SECTION 6 - JLG CONTROL SYSTEM
6-26
– JLG Lift –
3121813
FSW1 …
Displays footswitch status
NOTE: FSW1 is wired to the power module
FSW2 …
Displays footswitch status
NOTE: FSW2 is wired to the platform module
DRIVE CUTOUT …
Displays drive cutout switch status
ELEV. CUTOUT …
Displays elevation cutout switch status
FUNC. CUTOUT …
Displays function cutout switch status
BRAKES …
Displays brake pressure switch status
MAN.RELEASE …
Displays manual brake release switch status
TILT …
Displays measured vehicle tilt
The first value indicates tilt in the forward/ reverse direction (pitch)
The second value indicates tilt in the left/ right direction (roll)
DATALOG
MAX.TEMP …
Displays maximum measured heatsink temp.
MIN.TEMP …
Displays minimum measured heatsink temp.
MAX.BATTERY …
Displays maximum measured battery voltage
ON …
Displays total controller on (EMS) time
DRIVE …
Displays total controller drive operation time
PUMP …
Displays total controller pump running time
NOTE: includes all boom functions, steer and brake release
LIFT …
Displays total controller lift operation time
SWING …
Displays total controller swing operation time
TELE …
Displays total controller tele operation time
RENTAL …
Displays total controller operation time
NOTE: can be reset
ERASE RENTAL
Not available at password level 2
YES:ENTER, NO:ESC
ENTER resets rental datalog time to zero
VERSIONS
POWER …
Displays power module software version
PLATFORM
Displays platform module software version
GROUND
Displays ground module software version
POSITILT
Displays positrac/tilt module software version
ANALYSER …
Displays Analyzer software version
Table 6-7. Diagnostic Menu Descriptions