7 machine personality settings, Machine personality settings -9, Personality ranges/defaults -9 – JLG M600 Service Manual User Manual
Page 175
SECTION 6 - JLG CONTROL SYSTEM
3121813
– JLG Lift –
6-9
6.7 MACHINE PERSONALITY SETTINGS
NOTE: Personality settings can be adjusted within the
adjustment range in order to achieve optimum
machine performance.
Table 6-2. Personality Ranges/Defaults
FUNCTION
PERSONALITY
RANGE
DEFAULTS
DRIVE
ACCELeration
0.5s to 5.0s
1.0
DECELeration
0.1s to 2.0s
0.5
MINimum speed
0 to 25%
3
MAXimum speed
0 to 100%
72
ELEVATED MAXimum speed
0 to 25%
12
CREEP MAXimum speed
0 to 45%
30
POSITRAC time
0 to 60s
10
POSITRAC current
50-400 A
300A
4WD MINimum
0 to 50%
20
4WD MAXimum
0 to 100%
50
4WD Cutback
0 to 50%
30
LIFT
ACCELeration
0.5 to 5.0
0.7
DECELeration
0.1 to 3.0
1.0
MlNimum UP speed
0 to 20%
8
MAXimum UP speed
0 to 100
85
CREEP Maximum UP speed
0 to 50
25
MINimum DOWN speed
0 to 10
1
MAXimum DOWN speed
0 to 100
53
CREEP maximum DOWN speed
0 to 30
15
SWING
ACCELeration
0.5 to 5.0s
0.7
DECELeration
0.1 to 3.0s
1.5
MINimum LEFT speed
0 to 10%
1
MAXimum LEFT speed
0 to 60%
6
CREEP maximum LEFT speed
0 to 35%
4
MINimum RIGHT speed
0 to 10%
1
MAXimum RIGHT speed
0 to 60%
6
CREEP maximum RIGHT speed
0 to 35%
4