Machine - power up using the psl, Machine - power down, Changing the operator’s code – JLG 10MSP Operator Manual User Manual
Page 61

SECTION 3 - MACHINE OPERATION
3121227
– JLG Lift –
3-33
Machine - Power Up using the PSL™
NOTE: When entering the Operators Code on the keypad, a short
beep indicates a properly depressed key, a long beep
indicates an error in depressing key. If an error occurs,
you must restart the code entry process again.
1. Enter the programmed four digit Operators Code on the PSL
key pad. The ACCEPT - AMBER LED indicator will be lit if the
code is correct.
2. Press the keypad ON button. The ON - GREEN LED indicator
will light and power will be supplied to the Ground Control
Station.
3. At the ground control station, turn the main power selector
switch from OFF to either Platform Control Mode or Ground
Control Mode. At the Platform Control Console set the key
switch to the ON position.
4. The machine will now operate normally.
Machine - Power Down
1. At the Ground Control Station set the main power selector
switch to the OFF position.
2. Press the OFF button on the PSL keypad. No LEDs on the
PSL box will be lit.
Changing the Operator’s Code
The PSL Operators Code can be changed should the need occur.
A separate Permanent Code matched to the serial number of the
PSL box is included on a sheet in the PSL user manual supplied
with the machine.
1. Enter the Permanent Code on the key pad. The PROGRAM -
RED LED will be lit if correct code is entered.
NOTE: ON or OFF cannot be one of the four digits of the new
Operator’s code.
2. Enter a new four (4) digit Operator’s Code on the keypad.
The ACCEPT - AMBER LED will light up if the new Operator’s
Code is accepted.
3. Press the OFF button on the keypad to activate the new
Operator’s Code.
NOTE: The new Operator’s Code will remain in the PSL even
when power is removed from the equipment, or until that
code is changed again using the Permanent Code.