5 battery charging, Battery low voltage warning indicators, 5 battery charging -5 – JLG 10MSP Operator Manual User Manual
Page 33: Battery low voltage warning indicators -5, Harge as required (see section 3.5 on

SECTION 3 - MACHINE OPERATION
3121227
– JLG Lift –
3-5
3.5 BATTERY CHARGING
Battery Low Voltage Warning Indicators
The 10MSP Platform Control Console and Ground Control Station indicate battery low voltage at three (3) Warning Levels.
Table 3-1. Battery Low Voltage Warning Indicators.
WARNING
LEVEL
INDICATOR LOCATION
RESULT
ACTION REQUIRED
TO CLEAR FAULT
PLATFORM CONTROL LED
GROUND CONTROL LCD
LEVEL-1
• 3 LEDs/BARS Flashing with an
audible beep.
• Machine will Operate - No Con-
trol Functions Locked Out.
Charge batteries to a level of four (4)
LEDs/BARS or more before operating.
LEVEL-2
• 2 LEDs/BARS Flashing with an
audible beep.
• Platform Lift-UP Function is
Locked Out.
Charge batteries for a minimum of four
(4) continuous hours or eight (8)
LEDs/BARS lit before operating. (a)
LEVEL-3
• 1 LED/BAR Flashing with an
audible beep.
• Drive and Platform Lift-UP Func-
tions Locked Out.
Charge batteries for a minimum of four
(4) continuous hours or eight (8)
LEDs/BARS lit before operating. (a)
NOTE: (a) To maximize battery life, it is recommended that the factory supplied batteries be charged continuously for a minimum of 4 hours or until 8 bars
are lit on the ground station LCD Display before operating the machine. When drained to Warning Level 2 or 3, batteries must be charged until 8